B. Igniter Replacement
1. Use proper shut down procedures to shut down the
appliance and let it completely cool down and then
unplug it and remove the ash drawer.
2. Follow instructions to remove the ash pan found on
page 14. Remove the access plate directly above it by
removing the 2 screws just below the ash catcher.
3. The wire leads to the igniter are connected to the wire
harness with 1/4 inch male / female spade connectors.
These wires will pull forward approximately 4 to 5
inches (102mm to 127mm). Disconnect the spade
connections and remove the igniter from the chamber.
Loosen the thumb screw and slide igniter out.
4. Install new igniter into the chamber and tighten the
thumb screw. Re-connect the wires to the 2 leads with
the spade connectors.
5. Remove right side panel and pull wire leads back
toward the rear of the appliance to take-up the 4 to 5
inches (102mm to 107mm) previously pulled out. This
will keep the wires out of the way of the ash drawer.
Double check that the igniter wires are clear of any
movement, i.e. ash drawer, fire pot cleaning rod, etc.
6. Re-install the ash drawer and side panel and re-
connect the power.
Igniter Bracket
Thumb Screw
Figure 27.1
CAUTION
Shock Risk.
Do NOT remove grounding prong from
plug.
Plug directly into properly grounded 3
prong receptacle.
Route cord away from appliance.
Do NOT route cord under or in front of
appliance.
January 28, 2019
C. Blower Replacement
1. Convection Blower Replacement
a. Use proper shut down procedures to shut down the
appliance and let it completely cool.
b. The convection blower is located at the bottom rear
of the appliance. If an outside air kit is also installed,
depending on your particular installation you may
or may not have to remove the outside air flange. If
you do, remove the 2 screws using a Phillips head
screwdriver. You do not need to remove the flex pipe
from the flange.
c. Remove the lower rear screen by removing the 4
screws securing the screen to the appliance.
d. The motor is mounted on a removable bracket.
Remove the 2 screws just above the motor and the
whole assembly will tilt down and pull out.
e. Disconnect the wires from the blower. The wires
coming from the wiring harness are white, red and tan
and the wires coming from the blower are black, white
and red. The white connects to white, the red to red
and black to the tan color wire.
Igniter
Figure 27.2
7014-259E
CB1200 FREESTANDING
Convection Blower
27