Quadra-Fire CASTILE Series Owner's Manual page 21

Pellet insert
Hide thumbs Also See for CASTILE Series:
Table of Contents

Advertisement

10. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
Frequency: Yearly or more frequently depending on
ash build-up
By: Qualified Service Technician/Homeowner
The products of combustion will contain small particles
of fly-ash. The fly-ash will collect in the exhaust venting
system and restrict the flow of the flue gases. Incomplete
combustion, such as occurs during startup, shutdown, or
incorrect operation of the room appliance will lead to some
soot formation which will collect in the exhaust venting
system. The exhaust venting system should be inspected at
least once every year to determine if cleaning is necessary.
The venting system may need to be cleaned at least once a
year or more often depending upon the quality of your fuel
or if there is a lot of horizontal pipe sections. Ash will build
up more quickly in the horizontal sections.
11. Cleaning the Glass
Frequency: When clear view of the fire pot is obscure
By: Homeowner
a. Appliance must be completely cool before cleaning
glass.
b. Use a damp paper towel or any non-abrasive glass
cleaner. Wipe off with dry towel.
12. Door Latch Inspection
Frequency: Prior to heating season
By: Homeowner
The door latch is non-adjustable but the gasket between
the glass and firebox should be inspected periodically to
make sure there is a good seal.
NOTE: There is no gasket on the bottom of glass.
CAUTION
Handle glass assembly with care.
When cleaning glass:
Glass
Avoid striking, scratching or slamming
glass.
Do NOT clean glass when hot.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner
on white film.
Refer to maintenance instructions.
WARNING
Handle glass with care.
Inspect the gasket to ensure it is
Glass
undamaged.
Do NOT strike, slam or scratch glass.
Do NOT operate appliance with glass
assembly removed.
February 5, 2019
13. Cleaning Exhaust Blower - Requires No Lubrication
Frequency: Yearly or as needed
By: Quality Service Technician/Homeowner
Remove left & right brick. The exhaust blower is behind the
right brick. Vacuum this area thoroughly. See page 24 for
removing bricks. Re-install bricks when done.
14. Cleaning Convection Blower - Requires No
Lubrication
Frequency: Yearly or as needed
By: Qualified Service Technician
Task: Contact your local dealer.
15. Preparing Firebox for Non-Burn Season
Frequency: At the end of the heating season
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Remove all ash from the firebox and vacuum thoroughly.
c. Paint all exposed steel, including cast-iron.
Use the Touch-Up paint supplied with the appliance;
or,
Purchase paint from your local dealer.
Must use a high-temperature paint made
specifically for heating appliances.
Fire Risk
High ash fuels, or lack of maintenance, can
cause the fire pot to overfill. Follow proper
shutdown procedure if ash build up exceeds
half way point.
Failure to do so could result in smoking,
sooting and possible hopper fires.
7022-515I
CASTILE INSERT
WARNING
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Castilei-csb

Table of Contents