2 - INSTALLATION REQUIREMENTS

2.1 - Location

• The boiler must be located at least 300mm above any object to
allow the elements to be removed. At least 100mm is required at
the top of the boiler to allow for connection of pipework.
• 10mm is required at the sides of the unit.
• The boiler must be mounted on an internal solid masonry wall
capable of withstanding the weight of the product when full of
water.
• Consideration should be given to the rounting of electric cables to
the product and the wiring to a thermostat (if used).
• The location must be free from frost and excessives moisture.

2.2 - Fitting the boiler

2.21 - Opening case
The boiler may be opened by unscrewing the
bottom two bolts a couple of turns (they do not
need to be removed completely). The front
cover may then be pulled out from the bottom
and lifted off the two top pins.
Switch off the electricity supply to the
boiler before opening the internal cover.
Ascari - 12kW -page 8 -
100
10
10