ig
Heatindicator lightdoesnot illuminate
Possible Causes
1. The heaterswitch is notturnedon.
2. The machine power switch is not
turned on.
_iiill
/ WARNING:
To reduce the risk of fire, electric
shock or injury,unplug from the
outlet beforeservicing.
Remedies
1. Turnon the heaterswitchlocatedon
side of unit.
2. Both switches must be on
to activate the heat indicator light.
Reduced sprayORno spray
Possible cause
1.
Bladdermay be empty.
2.
2-in-1 tank may not be seatedproperly.
3.
Pump may havelost prime.
4.
The pumpbelt may be broken.
A.
B,
Remedies
1. Turnpowerswitchoff;,Refillbladder
with cleanhot tapwater andformula.
2. Turnpower switchoff; removetank
and reseattanks.
3. Turnpower switchoff; after 1 minute
turn onanddepress sprayrelease trigger
4. Turnpower switchoff and unplug
from theoutlet.Tocheckifa pumpbelthas
broken, y ou will needa flathead
screwdriver.
A. Insertthe bladeendinto the slot d the
belt accessdoorto release.Examine the
belt for breakage. Y oushouldbeable to see
the pumpbelt looped aroundthe motorshaft.
If it is brokenor missing,pleaserefer to
Replacement Partson page18.
A replacement belt maybeorderedat
www.bissell.com or bycallingBISSELL
Consumer S ervices at 800-237-7691.
Complete i nstallation instructions
will accompany the replacement b elt.
B. Whenreplacing belt access doorbesureto
line upslotsd belt access doorwith slotsin
machine, s lidedoorintoplace andsnapshut
Slots PumpBelt