Download Print this page

Fitting Instructions - 3M 6035 Technical Data Sheet

Reusable half face respirator
Hide thumbs Also See for 6035:

Advertisement

Fitting Instructions

Before assigning any respirator to be worn in a contaminated area,
we recommend that a qualitative or quantitative fit check be
performed before entering the workplace.
Fitting instructions must be followed each time the respirator is
worn.
1. Place the respirator over the mouth and nose, then pull the
harness over the crown of the head.
2. Take the bottom straps in both hands, place them at the back
of the neck and hook them together.
3. Tighten the top straps first by pulling on ends to achieve a
comfortable and secure fit.
4. Tighten bottom straps using either front or rear adjustments.
(Strap tension may be decreased by pushing out on back side
of buckles).
1
3
Materials
PART
Face Seal
Head Harness
Head Strap
Inhalation Valve
Exhalation Valve
Gasket
6000 Filter Body
6000 Filter Element
5000 / 2000 Series Filter material
2
4
Fit Check
Perform a positive and/or negative pressure fit check each time the
respirator is donned.
Positive pressure Face Fit check (all Filters except 3M™ 6035,
6038 / 2000 Series Filters).
1. Place the palm of the hand over the exhalation valve cover
and exhale gently.
2. If the respirator bulges slightly and no air leakage between the
face and the respirator is detected, a proper fit has been
achieved.
3. If air leakage is detected, reposition the respirator on the face
and/or readjust the tension of the strap to eliminate the
leakage.
4. Repeat the above face fit check.
5. If you cannot achieve a proper fit, do not enter the
contaminated area. See your supervisor.
Negative pressure face fit check (3M™ 6035, 6038 / 2000
Series Filters)
1. Push the filter cover down or press your thumbs into the
central indentation of the filters, inhale gently and hold your
breath for five or ten seconds.
2. If the respirator collapses slightly, a proper fit has been
achieved.
3. If air leakage is detected, reposition the respirator on the face
and/or readjust the tension of the straps to eliminate the
leakage.
4. Repeat the above face fit check.
5. If you cannot achieve a proper fit, do not enter the
contaminated area. See your supervisor.
MATERIAL
Thermoplastic elastomer
Polyethylene
Polyester / cotton / Polyisoprene
Polyisoprene
Silicone Rubber
Silicone Rubber
Polystryrene
Activated / Treated Carbon
Polypropylene

Advertisement

loading

This manual is also suitable for:

6000 series6098609960386096