3 General Programming
3.7 Libraries
Figure 3-31: Libraries in the TIA Portal
(1) "Project library"
Integrated in the project and managed with the project
Allows the reusability within the project
(2) "Global library"
Independent library
Use within several projects possible
A library includes two different types of storage of library elements:
(3) "Master copies"
Copy of configuration elements in the library (e.g. blocks, hardware, PLC
tag tables, etc.)
Copies are not connected with the elements in the project.
Master copies can also be made up several configuration elements.
(4) "Types"
Types are connected with your usage locations in the project. When types
are changed, the usage locations in the project can be updated
automatically.
Supported types are controller blocks (FCs, FBs), PLC data types, HMI
images, HMI faceplates, HMI UDT, scripts).
Subordinate elements are automatically typified.
Types are versioned: Changes can be made by creating a newer version.
There can only be one version of a used type within a controller.