5.
Hardware Configurations
Multiple options can be selected in the ETERNUS DX according to the customer's requirements. This chapter de-
scribes the installation conditions and standard installation rules for each component.
Configuration Schematics
The following diagrams show minimum and maximum configurations for ETERNUS DX storage systems.
■
Minimum Configuration
Figure 107 Minimum Configuration Diagram
CA
SW0
Memory
CPU
IOC0
BUD
EXP
CM#0
CPSU
IOM#0
DPSU
PANEL:
Operation panel
CE:
Controller Enclosure
CM:
Controller Module
CA:
Channel Adapter
Host Interface
Memory:
Cache Memory
BBU:
Battery Backup Unit
Backup power source in case of power outage
BUD:
Bootup and Utility Device
•
Backup area in case of power outage
Storage area for firmware
•
FAN:
Fan Unit
Cooling fan unit
SW:
Switch
PCI Express switch
IOC:
I/O Controller
Controller to control I/O
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)
CE
PANEL
SW1
SW1
IOC1
IOC0
MP
DE
PANEL
EXP
EXP
MP
Copyright 2019 FUJITSU LIMITED
CA
BBU
SW0
Memory
CPU
IOC1
BUD
EXP
CM#1
CPSU
IOM#1
DPSU
167