4.3 Modem

When using an integral or connected modem, the interface of the volume corrector (except EK280
parameterised as follows:
2
AD
Address
Md.S2
2:0705
DF.S2
2:0707
Bd.S2
2:0708
TypS2
2:070A
Num.T
2:0720
CW1.S
5:0150
CW1.E
5:0158
CW2.S
6:0150
CW2.E
6:0158
1:01FB
2:0709
*1) When using a modem without automatic call acceptance (standard case), Md.S2 = "3" must be set and
MD.S2 = "5" for modems with automatic call acceptance (e.g. with an FE260 with the option "Local
interfaces" or "CL interface").
*2) 19200 Bd is standard. With longer lengths of cable between the FE260 and the volume corrector (refer
to Chapter 0, page 10) and when using the option "Local interfaces" or "CL interface", the baud rate may
be set to a maximum of 9600 Bd.
When using an FE260, the starting baud rate "Bd.S2" and the "Identification baud rate" (address 2:0709)
must always be set to the same value.
*3) The setting of the type of interface is only needed with those types of volume corrector where "TypS2" is
present in the display (e.g. EK260).
*4) The adjustable number of ringing tones (rings) before call acceptance depends on the modem used.
With a GSM modem it must be set to "2" and with other modems to a value between "2" and "9".
With a modem with automatic call acceptance, "Num.T" has no significance.
*5) Volume correctors in the LIS-200 range, such as the EK260 and EK280, offer at least two time windows
within which calls can be accepted for data interrogation. Outside of these time windows calls are
ignored, so that, for example, a person located in the station can be called via a telephone connected to
the same telephone line.
*6) The values with the addresses 1:01FB and 2:0709 are not always available in the volume corrector
display. They can be changed, for example, via the optical interface using the parameterisation software
"enSuite". The standard setting is "1:01FB = 1" and "2:0709 = 19200".
1
Please parameterize the EK280 according its Application Manual
Abbreviation in the interface menu "Ser.IO" in the display of the volume corrector
2
Operating Manual
Designation
Mode
Data format
Initial baud rate
Type of interface
Rings before call accept.
Call Time Window 1 Start
Call Time Window 1 End
Call Time Window 2 Start
Call Time Window 2 End
Activation with external power
supply
"Identification baud rate"
Setting
Meaning
3 or 5
0
7 data bits, even parity, 1
stop bit ("7e1")
19200 or 9600 baud
2
RS-485
1
Remains continuously active
19200 or 9600 baud
17
1
) must be
Rem.
*1)
*2)
*3)
*4)
*5)
*6)
*2), *6)