Decoder Configurations

This chapter will list most of the decoding related parameters to configure the activity
®
of the reader. The "Decoding" Tab page inside the DataMax
Configuration Program
includes all the related configurations.

General Settings

Reread Delay

This is an important parameter in this mode which sets the time period before the
reader can read the same barcode a second time. Setting a reread delay protects
against accidental rereads the same barcode. Longer delays are effective in
minimizing accidental rereads. Use shorter delays in applications where repetitive
barcode scanning is required.
Go to the "Decoding" Tab page and input the desired delay value into the edit box
"Re-read Delay (ms)". Default = 750ms.
This setting will take effect on "Streaming Presentation Mode" and "Presentation
Mode".

Read TimeOut

Use this selection to set a time-out (in milliseconds) of the reader's trigger when
using external signal or commands to trigger the reader.
Once the reader has timed out, you can activate the reader either by re-start external
signal or using the trigger command.
This parameter can only work in External Trigger mode or Self-Trigger mode.

Good Read Delay

This sets the minimum amount of the time before the reader can read another bar
code.
This parameter can only work in External Trigger mode or Self-Trigger mode.