Daikin FTKS50BVMA8 Service Manual page 12

Indoor unit removal procedure
Hide thumbs Also See for FTKS50BVMA8:
Table of Contents

Advertisement

PCBs
Step
Cut the clamp.
4
5
The signal receiver unit
has 4 PCBs.
Unfasten the hooks and
remove each PCB.
Disconnect every
connector from each
PCB.
Cut the clamp.
6
7
Unfasten the 2 hooks
on the lower side, and
then the 2 hooks on the
upper side.
Remove the control
PCB.
10
Procedure
Display PCB
Signal receiver PCB
INTELLIGENT EYE
Buzzer PCB
sensor PCB
Clamp
Upper hook
Lower hook
Clamp
(R18795)
(R2783)
(R18796)
Control PCB
(R17912)
Si041253_A
Points
Removal Procedure

Hide quick links: