Daikin VRV RXYQ5P7W1B Technical Data Manual page 129

Small footprint combination, r410a, air conditioning systems
Hide thumbs Also See for VRV RXYQ5P7W1B:
Table of Contents

Advertisement

7
Wiring diagram
7 - 1 Wiring diagram
RXYQ14,16,18P
3
Position of M1~3C, M1,2F
El. compo. box
M1C
Outer shell
A1P
Printed circuit board (Main)
A2P
Printed circuit board (Noise filter)
A3P
Printed circuit board (Inverter)
A4P, A8P
Printed circuit board (Fan)
A5P
Printed circuit board (ABC I/P)
A6P, A7P
Printed circuit board (Current sensor)
BS1 ~ BS5
Push button switch (Mode, Set, Return, Test, Reset)
C1
Capacitor
C63, C66
Capacitor
DS1, DS2
Dip switch
E1HC~E3HC
Crankcase heater
F1U
Fuse (250V, 8A,
F1U, F2U
Fuse (250V, 3.15A,
F5U
Field Fuse
F400U
Fuse (250V, 6.3A,
H1P ~ H8P
Pilot lamp (Service monitor-orange)
[H2P] Prepare, test ......................... flickering
HAP
Pilot lamp (Service monitor-green)
K1
Magnetic relay
K2
Magnetic contactor (M1C)
K2M, K3M
Magnetic contactor (M2C, M3C)
K1R, K2R
Magnetic relais (K2M, K3M)
: Field wiring
: Terminal strip
: Connector
: Terminal
: Protective earth (screw)
NOTES
1
This wiring diagram applies only to the outdoor unit.
2
When using the option adaptor, refer to the installation manual.
3
Refer to the installation manual, for connection wiring to indoor-outdoor transmission F1-F2, outdoor-outdoor transmission F1-F2, outdoor-multi transmission Q1 - Q2 and on how to use BS1~BS5 and DS1, DS2 switch.
4
Do not operate the unit by short-circuiting protection device S1PH.
128
• Outdoor Units • VRV
Power supply
400V 3N~50Hz
M2C
M3C
W
U
V
Detail of M1C~M3C
K3R
K4R
K5R
K7R
K8R
K9R
L1R
M1C~M3C
M1F, M2F
PS
Q1RP
) (A4P, A8P)
Q1DI
) (A1P)
R10
R50, R59
) (A2P)
R95
R1T
R1T
Malfuntion detection .... light up
R2T
R31T
R32T
R33T
R4T
R5T
COLORS : BLK : Black
®
• VRV
Systems • Outdoor Units
®
Heat Pump • RXYQ5-54P7W1B(A)
14,16,18 HP
Cool/heat selector
A
B
Cool
Heat
Cool
S2S
Heat
Cool/heat selector (option)
Male connector: RED
Female connector: WHT
Magnetic relay (Y1S)
Magnetic relay (Y2S)
Magnetic relay (Y3S)
Magnetic relay (E1HC)
Magnetic relay (E2HC)
Magnetic relay (E3HC)
Reactor
Motor (Compressor)
Motor (Fan)
Switching power supply (A1P, A3P)
Phase reversal detect circuit
Earth leakage breaker
Resistor (Current sensor) (A4P, A8P)
Resistor
Resistor (Current limiting)
Thermistor (Air) (A1P)
Thermistor (Fin) (A3P)
Thermistor (Suction)
Thermistor (M1C Discharge)
Thermistor (M2C Discharge)
Thermistor (M3C Discharge)
Thermistor (Heat exchanger deicer)
Thermistor (Heat exchanger outlet)
ORG : Orange
BLU : Blue
PNK : Pink
BRN : Brown
RED : Red
GRN : Green
WHT : White
GRY : Grey
YLW : Yellow
ON
ON
(Note 2)
OFF
OFF
In-Out
Out-Out
Out-Multi
C
F1
F2
F1
F2
Q1
Q2
(Note 3)
Male connector: BLU
Female connector: WHT
S1S
Fan
Indoor
Outdoor
Outdoor
(F1)(F2)
(F1)(F2)
(Q1)(Q2)
Position in switch box
Front layer
Rear layer
R6T
Thermistor (Liquid pipe)
R7T
Thermistor (Accumulator)
S1NPH
Pressure sensor (High)
S1NPL
Pressure sensor (Low)
S1PH~S3HP
Pressure switch (High)
T1A
Current sensor (A6P, A7P)
SD1
Safety devices input
V1R
Power module (A4P, A8P)
V1R, V2R
Power module (A3P)
X1A~X4A
Connector (M1F, M2F)
X1M
Terminal strip (Power supply)
X1M
Terminal strip (Control) (A1P)
X1M
Terminal strip (A5P)
Y1E
Electronic expansion valve (Main)
Y2E
Electronic expansion valve (Subcool)
Y1S
Solenoid valve (Hot gas)
Y2S
Solenoid valve (Oil return)
Y3S
Solenoid valve (4 way valve)
Z1C ~ Z9C
Noise filter (Ferrity core)
Z1F
Noise filter (With surge absorber)
Cool/heat selector
S1S
Selector switch (Fan/cool - heat)
S2S
Selector switch (Cool - heat)
2TW27276-1A