Emerson Easyheat Warm Tiles Operating & Installation Instructions Manual page 5

Fgs
Table of Contents

Advertisement

Available languages

Available languages

S
S
5/2 Day
S
.
Wake
1 8 8 8
S
S
7 Day
Leave
Set
Return
Temp
Sleep
Wood
Actual Floor Temp
Tile
Backlight
1 8 88
Auto
AM
:
Off
Min
Hold
Sensor
PM
Mo Tu We Th Fr Sa Su
Figure 7
E1. Setting the Time and Day
Press the Settings button once, the display is
disabled except the Hour, Minute, AM or PM digits
flash. This signifies that the time is waiting to be
adjusted. See Figure 9.
1. Press the Up or Down button to adjust the hours
and minutes (including AM/PM). Press the Next/
Save button once to accept the time setting and
move to the Day setting.
2. Press the Up or Down button to set the Day –the
"Day" symbol flashes – See Fig. 10. Press the Up
or Down button to set the day. You can now
Advance to Next Menu or Exit Without Saving or
Save and Exit.
E2. Other Settings
1. In the Units menu, the previously selected
temperature units flash (F or C). See Fig. 11. Press
the Up or Down button to change units.
2. In the Program menu, you can select either 5/2
or 7 Day mode. (You can also change the details
of the automatic program for each mode – see
Section H). Use Up or Down buttons to select
mode.
3. In the Backlight menu, you can change the
time that the backlight stays on after the last
button is pressed – options are 2 minutes or On
continuously. Use Up or down buttons to select.
4. In the Floor Type menu, you can select the type
of flooring (Tile or Wood) for your application.
F. Temporary and Permanent - Floor
Temperature Settings
Temporary - At any time when the thermostat is in
the ON position (Auto mode icon will show on LCD),
the setpoint temperature setting can be temporarily
changed. By pressing either the UP or DOWN
button once, the floor temperature digits will flash.
Press the UP or DOWN button again to obtain the
desired temperature. Press the Hold button once to
temporarily save the setting. When the buttons are
not pressed for four seconds, it will automatically
1 2 00
1 2 00
:
:
PM
Mo
Figure 8
Figure 9
PM
Mo
Figure 10
save the last setting. The thermostat will use the new
temporary temperature setting until the next event
time is reached. The Auto period icon (Wake, Leave,
Return or Sleep) and Hold will flash slowly.
Permanent – After adjusting the setpoint temperature
as noted above in "Temporary" section, the new
setpoint can be made permanent by pressing the
Hold button a second time. The Hold icon will show
on the display and will not flash. The Auto icon will
not be displayed. To disable the permanent hold
function, simply press the Hold button once again
– the thermostat returns to Auto mode and the
setpoint temperature will be in accordance with the
Automatic Program.
G. Personalizing Your Floor Comfort Schedule
The FGS series thermostats offer two programming
modes to personalize your floor comfort and
maximize energy savings. The first program mode is
the 5/2 Day mode, which groups Monday – Friday
as the "5" group and Saturday and Sunday as
the "2" group. The second program mode is the
7 Day mode, which allows you to program each
day individually to suit your specific schedule. Each
program mode allows four unique time/temperature
settings ("events"). Usually, you would select the
program mode that best suits your schedule. (Hint: It
is easier and quicker to modify the 5/2 Day program
than the 7 Day program, so choose the 5/2 Day if it
better suits your schedule.)
Both the 5/2 Day and 7 Day modes are pre-
programmed, as noted in "Quick Start" above.
These programs are easily modified, as explained in
the appropriate sections below.
Prior to modifying these programs, you should
consider that floors take time to heat up and cool
down to their set temperatures. Keep in mind that
you may want to set the Floor Temp about one
hour before you want the floor to be warm, this
allows adequate heat up time. Conversely, you
can set the Floor Temp to decrease about one hour
before you want the floor to reach its cool down
temperature.
5
F
Backlight
Figure 11
Figure 12
2
Min