Operational Cam Follower; Operational Contact Removal; Operational Magnet Assembly Removal - IBM Selectric Maintenance Manual

I/o keyboardless printer
Hide thumbs Also See for Selectric:
Table of Contents

Advertisement

FIGURE 40.
Operational Cam Check Pawl and Escapement
Cam Follower Removal
OPERATIONAL CAM FOLLOWER REMOVAL
1.
Remove the C-c1ips from the cam-follower pivot shaft
(#1, Figure 41).
2.
Remove the auxiliary cam-follower spring (#2, Figure4l).
3.
Work the shaft to the right until the desired part is free.
FIGURE 41.
Operational Cam Follower Removal
OPERATIONAL CONTACT REMOVAL
1.
Remove the right rear mounting leg (#1, Figure 42).
2.
Remove the two mounting screws (#2, Figure 42) and re
move the contact assembly.
3-11
FIGURE 42.
Operational Contact Removal
OPERATIONAL MAGNET ASSEMBLY REMOVAL
1.
Perform the Shift-Magnet-Assembly Removal.
2.
Remove the actuator-arm spring (#1, Figure 43).
3.
Remove the two mounting screws (#2, Figure 43).
4.
Remove the actuator-arm pivot screw (#3, Figure 43).
5.
Remove the armature-link clevises (#4, Figure 43).
6.
Remove the mounting screw (#1, Figure 44).
7.
Remove the nut (#2, Figure 44) and carefully remove the
magnet assembly.
FIGURE 43.
Operational Magnet Assembly Removal

Hide quick links: