Download Print this page
TFC RF205-TS Instructions

TFC RF205-TS Instructions

Programmable rf room thermostat

Advertisement

Quick Links

RF205-TS programmable room thermostat (transmitter)
1.
General
The RF205-TS is a radio controlled room thermostat which requires no wiring and is designed to be fitted in a
conventional household installation, at a maximum 30 metres range of the T55 "boiler module", which is a
boiler-mounted modular receiver.
The T55 receiver must be installed by a qualified installation engineer. Do not place it too close to objects
which might interfere with the radio signal. It is preferable to mount the receiver such that an imaginary
straight line between it and the transmitter thermostat is not obscured by the boiler or any other large metal
objects such as kitchen appliances. When installing these devices, please avoid touching the PCB as static
damage can occur.
The RF205 control set has already been commissioned, or matched, in the factory. Just connect power to the
receiver / put batteries in the transmitter, and the set will communicate. If for any reason you wish to verify
the RF link please refer to the fourth option under section 7. Configuration Setting
2.
Technical data
Operating voltage: receiver: 230VAC ± 10%; transmitter: 3.0V ± 0.2 V DC
Time regulation: < 3s/Day
Consumption: <0.06W
Accuracy: ±0.5ºC
Thermostat size: 136mm x 90mm x 30mm
3. T55 receiver fitting and wiring
RF205 Series
Programmable RF room thermostat
Transmitter power supply: 2 x AA alkaline
Set-point range: 5.0ºC - 35.0ºC
Load current: 2A
Receiver size: 60mm x 60mm x 32mm
Transmitter link via RF Frequency: 433MHz
LED indicator for matching/output status
Recessed button for RF matching
Connections:
1 – Neutral input
2 – Live input
3 – Common input
4 – Normally open output
RF205 BM(EN) V1 2016-11-15
T55 (Receiver)

Advertisement

loading

Summary of Contents for TFC RF205-TS

  • Page 1 T55 (Receiver) General The RF205-TS is a radio controlled room thermostat which requires no wiring and is designed to be fitted in a conventional household installation, at a maximum 30 metres range of the T55 “boiler module”, which is a boiler-mounted modular receiver.
  • Page 2 2) Release the top half of the housing (there is a 1) Loosen the screws on the underside of the small clip adjacent to the battery compartment) RF205-TS. and open the device. Be careful not to touch the PCB, in case of static discharge.
  • Page 3 RF205 Series Programmable RF room thermostat 6. Menu & setting 6.1. Temperature setting. Press once, the backlight will turn on. Then Press to increase the set temperature, or press , to reduce the set temperature. From Programme Run Mode, this will initiate Temporary Manual Mode, which will revert to Programme Run Mode at the next timed setting.
  • Page 4 RF205 Series Programmable RF room thermostat 7. Configuration Setting Enter into Configuration Setting by pressing briefly during Power-off Status. Then press sequentially to view and amend (if required) parameters noted below. You can confirm any changed parameters by pressing . Press the Power Button to exit configuration.

This manual is also suitable for:

T55Rf205 series