• NORMAL: the unit will run in Medium ventilation/HIGH Heat. And, if the ambient humidity
is less than the set humidity, the unit will run in Medium fan speed only, no Heat.
• TURBO: the unit will run in HIGH ventilation/HIGH Heat. And, when the ambient
humidity is less than the set humidity, the unit will run in HIGH fan speed only, no Heat.
• AUTO BUTTON: By pressing this button, the unit will work automatically as below:
– Ambient humidity ≥ 70% .... unit works in HIGH speed dehumidify.
– 70% > ambient humidity ≥ 55% .... unit works in LOW speed dehumidify
– Ambient humidity < 55%, .... unit stops for 30mins -> fan resumes to work, to
detect the ambient humidity. If higher than 55%, the unit resumes to work.
• OPERATION MODES: As an additional safety procedure, the dehumidifier rests for
at least 30 minutes every 8 hours of operation. Every 30 minutes of rest, the fan mode
turns on to check the ambient humidity and if needed (depending on the set mode),
the dehumidifier will resume operation.
• DRY CLOTHES (LAUNDRY) BUTTON: This mode is designed to really dry out a
room to allow clothes to dry faster. The dehumidifier will work continuously at a target
humidity level of 40% humidity / high fan/high heat. The DRY CLOTHES indicator will
light up. The dehumidify will also rest every 8 hours of operation.
– Under this mode, the fan speed is always fixed at HIGH speed and is not adjustable.
• HUMIDITY BUTTON: Set the humidity level you need: CNT (continuous dehumidify),
40%, 50%, 60% or 70%. The set HUMIDIFY level will show on the LED display.
If the HUMIDITY button is not set, the unit will work in the default setting: 50%
humidity / low fan / low heat.
• CONTINUOUS DEHUMIDIFY MODE: The dehumidifier rests for 30 minutes
between every 8 hours of dehumidification (at the set humidity level).
– Continuous dehumidify mode + Ambient humidity less than 35%
The heater works for 15 minutes, then rests for a few minutes and repeats this cycle,
unless the humidity level rises.
• Usage when ambient temperature is higher than 36ºC
The heater stops, but the fan keeps running to check humidity, then follows the
general logic of stopping for 30 minutes if the desired humidity is reached.
• Working with humidity setting: 40%, 50%, 60% or 70%
The dehumidifier rests for 30 minutes between every 8 hours of dehumidification (at
the set humidity level).