9.2 EC Motor (ECM) Data ......................... 43 10. SPECIFICATIONS ........................... 44 OMEGA Heat Pumps 3325A Orlando Dr. Mississauga, ON, L4V 1C5 T. 905.670.2269 F. 905.670.3822 omega-heatpump.com omega@omega-heatpump.com Omega has a policy of continuous product improvement and reserves the right to change design specifications without notice. www.omega-heatpump.com...
The chassis produc- Omega VSHP units come with a slide out chassis and a tion and testing line features a computer controlled 6- blower assembly which are easily accessible through the step quality control (QC) system to ensure that every front return air panel.
Riser mounting location flexibility Certification Acoustical Design Features—Standard Silver Series All Omega products are listed by 1 inch high density sound insulation throughout ETL (Intertek) Omega products conform to UL STD 1995 Double isolated chassis base to isolate the ...
OMEGA | OMEGA-VSHP.F-PGD-1904 2. PRODUCT DETAILS 2.1 Standard & Optional Features STANDARD FEATURES Cabinet The galvanized sheet metal cabinet is designed for structural rigidity, installation flexibility, and serviceability. Cabi- net heights of up to 120” are available. Cabinet interior is lined with 1” thick acoustic, thermal, mould and fire re- sistant insulation rated to meet NFPA 90.
Page 7
Hi-static PSC and ECM options are available depending on external static design conditions. Return Air Panel Omega offers 2 styles of return air panels. Acoustic panel, stamped blade style, is designed to be as narrow as possible making it ideal for space constrained installations. Perimeter, enhanced aesthetic, is a noise attenuating insulated door style.
Omega offers two distinct cabinet options for VSHP units: the Silver and Gold series (shown below). Silver series is the Omega standard product built as free standing design. The Gold series cabinet is shipped to the field in two sections. The base section contains all the components and top section is a supply discharge plenum attached to base section using the factory provide flex duct connector.
OMEGA-VSHP.F-PGD-1904 | OME GA 2.3 Optional Fresh Outside Air Duct Optional built-in Fresh Air Duct is suited for applications where the Energy Recovery Ventilator (ERV) unit is remote mounted. The factory installed fresh air intake accepts fresh air connection from a remote mounted ERV. Refer to Section 5.3 to see different configurations available for location of fresh outside air duct.
OMEGA | OMEGA-VSHP.F-PGD-1904 2.4 Assembly View Supply, Return and Condensate Risers “Knockout” style supply air openings (Front/Back/Side) Electrical Box w/ Microprocessor Controller Direct driver blower motor assembly Chassis Service Cover Panel Return Air Panel (Acoustic) SS Drain Pan Air Filter...
OMEGA-VSHP.F-PGD-1904 | OME GA 2.5 Noise Attenuation Features Omega Heat Pump units offer up to 5 separate methods of vibrational isolation (Shown below). Flex Duct Isolator Units with the optional Gold Series option feature a flexi- ble canvas duct connection...
OMEGA | OMEGA-VSHP.F-PGD-1904 3. CABINET DIMENSIONAL INFORMATION 3.1 Standard Silver Series Cabinet Figure 7 Silver Series Dimensional Drawing (Drawing not to scale, dimensions are subject to change) Table 1 VSHP Cabinet Dimensions (Silver & Gold Series) Dimensions (in) Cabinet Model Size "W"...
OMEGA-VSHP.F-PGD-1904 | OME GA 3.2 Optional Gold Series Cabinet with Acoustic Plenum Figure 8 Gold Series Dimensional Drawing (Drawing not to scale, dimensions are subject to change) www.omega-heatpump.com...
OMEGA | OMEGA-VSHP.F-PGD-1904 4. RISERS & HOSE KITS 4.1 Riser Handing Conventions (Top View) Back (BK-SR) Left Hand (LH-SR) Right Hand Riser (RH-SR) Back (BK-RS) Left Hand (LH-RS) Right Hand (RH-RS) Legend: = Supply Riser = Condensate Riser = Return Riser...
A Base Datum indicates where bottom of riser will be located relative to floor. Upon request Omega will swage riser pipes of same pipe size for connection to units on the floor below. ...
OMEGA | OMEGA-VSHP.F-PGD-1904 5. SUPPLY DISCHARGE & RETURN AIR 5.1 “Knockout” Discharge Opening Units comes with standard “Knockout” style discharge openings for field configuration. This allows for custom discharge configurations based on site requirements. Figure 14 Standard “Knockout” Style Openings...
OMEGA-VSHP.F-PGD-1904 | OME GA 5.2 Supply Discharge Openings Note: Discharge opening not available on side with risers Figure 15 Supply Discharge Openings Table 4 Supply Air Opening Sizes VSHP Supply Discharge Opening (W X H) inches Model Horizontal 14 x 8...
OMEGA | OMEGA-VSHP.F-PGD-1904 5.3 Top Supply Discharge Openings with Optional Fresh Air Duct Top discharge for VSHP cabinet with fresh air duct is available in two orientations: Horizontal and Vertical. Each orientation contains four possible configuration options for fresh air duct location.
OMEGA-VSHP.F-PGD-1904 | OME GA 5.4 Line of Sight Baffle Optional Line of Sight Baffles (LOSB) can be supplied inside discharge plenums on units with (2) two or more horizontal discharge openings. The LOSB provide occupant privacy between adjacent rooms. Two configura- tions (LSB-LR or LSB-RL) of LOSB are available based on the unit discharge arrangement.
Page 23
OMEGA-VSHP.F-PGD-1904 | OME GA 5.5 Acoustic Front Return Air Panel & Furring Details (Cont’d) Right Riser Location Back Riser Location (Left is Mirror) Figure 19 Acoustic Panel Furring Detail—Top View Notes: The framing should be installed for a maximum 0.5” maximum clearance between the heat pump return air flange and the return air panel throat opening flange.
Page 24
OMEGA | OMEGA-VSHP.F-PGD-1904 5.5 Acoustic Front Return Air Panel & Furring Details (Cont’d) 54 - 1/4” Figure 20 Acoustic Panel Furring Detail—Front & Side View = Base Height (Min 5", increases in 1" increments) = Base Height + 1.250" = Base Height + 2.375"...
OMEGA-VSHP.F-PGD-1904 | OME GA 5.6 Perimeter Front Return Air Panel & Furring Details Figure 21 Perimeter Panel Dimensional Drawing Table 8 Perimeter Panel Sizes Perimeter RA Panel Dimensions (inches) Cabinet Model Size VSHP 020 VSHP 030 58 1/4 19 1/8...
Page 26
OMEGA | OMEGA-VSHP.F-PGD-1904 5.6 Perimeter Front Return Air Panel & Furring Details (Cont’d) Right Riser Location Back Riser Location (Left is Mirror) Figure 22 Perimeter Panel Furring Drawing Notes: The framing should be installed for a maximum 0.5” maximum clearance between the heat pump return air flange and the return air panel throat opening flange.
Page 27
OMEGA-VSHP.F-PGD-1904 | OME GA 5.6 Perimeter Front Return Air Panel & Furring Details (Cont’d) 58 - 1/2” Figure 24 Perimeter Panel Vertical Furring Drawing = Base Height (Min 5", increases in 1" increments) = Base Height - 0.875" = Base Height + 0.375"...
OMEGA-VSHP.F-PGD-1904 | OME GA 6.4 Thermostat Wiring Details Note: Factory supplied 6-wire 24 inch thermostat cable coiled up in low- voltage compartment of electrical box for field wiring to thermostat. Field Supplied 7-Wire thermostat cable shown (used with 3-speed thermostat). Factory provided 6-wire is not wired to terminal G3.
OMEGA | OMEGA-VSHP.F-PGD-1904 7. PERFORMANCE DATA 7.1 ISO Data Unit ISO Data COOLING HEATING MODEL WATER VOLTAGE FLOW FLOW BTUH WATT BTUH WATT FRIG. (GPM) (SCFM) SIZE (ft w.c.) VSHP 20 R410 208-230/60/1 5800 12.20 7200 4.30 VSHP 30 R410 208-230/60/1 11.0...
OMEGA-VSHP.F-PGD-1904 | OME GA 8.2 Design Limits Cooling Heating Air Limits Std. Entering Air Temperature (EAT) Min. Entering Air Temperature (EAT) Max. Entering Air Temperature (EAT) Standard Range Geothermal Range Fluid Limits Heat- Cooling Cooling Heating Std. Entering Fluid Temperature (EFT) Min.
OMEGA | OMEGA-VSHP.F-PGD-1904 9. FAN & MOTOR DATA 9.1 PSC Motor Data External Static Pressure (in w.g.) Min. Rated Model Speed SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM HIGH HIGH HIGH HIGH HIGH HIGH 1010 1045 HIGH 1155...
OMEGA-VSHP.F-PGD-1904 | OME GA 9.2 EC Motor (ECM) Data External External Static Pressure (in w .g.) EC Motor Static Min. Rated Model 0.05 0.15 0.25 0.35 0.45 0.55 Speed Pressure SCFM SCFM Option SCFM SCFM SCFM SCFM SCFM SCFM SCFM...
L) (Type M) copper, with (factory) (field) mounted shut-off ball valves on each supply and return riser. Valves shall be brass and Install Omega series Vertical Stack Heat Pumps as indicated on rated for 400 psig. A (Type M/DWV) condensate riser shall be the plans and capacities listed in the schedule and specifications.
Page 47
OMEGA-VSHP.F-PGD-1904 | OME GA SPECIFICATIONS (CONT’D) bonded to aluminum fins. Coil shall be sized to meet scheduled setback, night setup, and day/night time clock operation. Thermo- performance for cooling and heating. Provide 1” T/A filter on coil stat shall have system “On-Off”, temperature “Heat-Auto-Cool” and face.
Page 48
OMEGA | OMEGA-VSHP.F-PGD-1904 OMEGA Heat Pumps 3325A Orlando Dr. Mississauga, ON, L4V 1C5 T. 905.670.2269 F. 905.670.3822 omega-heatpump.com omega@omega-heatpump.com Omega has a policy of continuous product improvement and reserves the right to change design specifications without notice. www.omega-heatpump.com...