Brinkmann KTF25/170 Operating Instructions Manual
Brinkmann KTF25/170 Operating Instructions Manual

Brinkmann KTF25/170 Operating Instructions Manual

Immersion pump
Hide thumbs Also See for KTF25/170:

Advertisement

Quick Links

BE5400

Operating Instructions

(Translation of original)
BRINKMANN Immersion Pumps
KTF25 ... 83
 Brinkmann Pumpen
10/2016
1
9
Edition
Page
of

Advertisement

Table of Contents
loading

Summary of Contents for Brinkmann KTF25/170

  • Page 1: Operating Instructions

    BE5400 Operating Instructions (Translation of original) BRINKMANN Immersion Pumps KTF25 … 83  Brinkmann Pumpen 10/2016 Edition Page...
  • Page 2: Table Of Contents

    Brinkmann Immersions pumps of the series KTF25 ... 83 Contents Indication to the manual ........2 8 Servicing and Maintenance ....... 6 9 Trouble shooter’s guide ........7 Description of product ........2-3 Safety instructions ..........4 10 Spare part ............8 Transport and storage ........
  • Page 3 Technical data Number of Max. del. Max. del. Height Depth of Weight Power Noise stage pressure bar / volume immersion level Type spec. weight 1 l/min H mm h mm dBA / 50 Hz KTF25 / 120 0.045 KTF40 / 120 0.055 KTF51 / 120 0.075...
  • Page 4: Safety Instructions

    3 Safety instructions Safety instructions relevant for operation  If hot or cold machine components involve When operating the pump. the safety instructions contained in this manual. the relevant national hazards. they must be guarded against acci- accident prevention regulations and any other dental contact.
  • Page 5: Installation And Connection

    5 Installation and Connection Electric wiring Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. Pumps must be mounted securely. Piping. tank and All service work must be carried out by quali- pumps must be mounted without any tension.
  • Page 6: Start Up / Shut Down

    6 Start up / Shut down 8 Servicing and Maintenance Start up ATTENTION ATTENTION The surface of the motor must be kept free of dirt. Switch off at the mains. The motor shaft is spinning in permanently greased After connection the electrical wires. close the ball bearings (with special grease and increased terminal box.
  • Page 7: Trouble Shooter's Guide

    9 Trouble shooter’s guide Fault Cause Remedy Motor does not start. no motor At least two of the power supply Check fuses. terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start. humming noise One of the supply leads has failed See above Impeller faulty...
  • Page 8: Spare Part

    10 Spare part 10.1 Spare part list for the immersion pumps of the series KTF25 ... 83 Item Description Stator with terminal board End shield / KTF54. 83 Terminal box Fan cover Ball bearing DIN 625 Ball bearing DIN 625 Gasket 10 Slotted cheese head screw DIN 84...