Table Of Contents; Indication To The Manual; Description Of Product - Brinkmann KTF25/170 Operating Instructions Manual

Immersion pump
Hide thumbs Also See for KTF25/170:
Table of Contents

Advertisement

Brinkmann Immersions pumps of the series KTF25 ... 83
Contents
1
Indication to the manual .................................... 2
2
Description of product .................................... 2-3
3
Safety instructions ............................................. 4
4
Transport and storage ....................................... 4
5
Installation and connection ................................ 5
6
Start up / Shut down .......................................... 6
7
Operation ........................................................... 6

1 Indication to the manual

This operating manual gives basic instructions
which are to be observed during installation, opera-
tion and maintenance of the pump. It is therefore
imperative that this manual be read by the respon-
sible personnel and operator prior to assembly and
commissioning. It is always to be kept available at
the installation site.
1.1
Identification of safety instructions in the
operating manual
Safety instructions given in this manual non-
compliance with which would affect safety are
identified by the following symbol
Safety sign according with ISO 3864 - B.3.1
or where electrical safety is involved, with:
Safety sign according with ISO 3864 - B.3.6
Where non-compliance with the safety instructions
may cause a risk to the machine and it's function
the word
ATTENTION
is inserted.

2 Description of product

2.1
General description of the pump
Pumps in plastics of this type are one or multi-stage
rotary pumps where the impellers are fixed on the
driving shaft extension. Pump and motor form a
compact and space-saving unit.
Vertically mounted pumps are equipped with a
mounting flange. The pump end immerses into the
tank and the motor extends vertically above the
tank.
BE5400
8 Servicing and Maintenance ............................... 6
9 Trouble shooter's guide ..................................... 7
10 Spare part ......................................................... 8
11 Disposal ............................................................ 8
12 EC declaration of conformity ............................. 9
2.2
Intended use
The immersion pumps of the series KTF are suita-
ble for various water supply problems within the
limiting application in accordance with table 1.
Limit of Application (Table 1)
Type
Mediums
Kinetic viscosity
of the medium
Temperature of
medium
Particle-size in
the medium
max. solid part
to delivery
medium ratio by
weight:
min. delivery
volume
Dry running
Switching-on
frequency per
hour
Ambient
temperature
Set-up altitude
The pumps are to be operated within their design
limits. Applications outside of these limits are not
approved. The manufacturer is not responsible for
any damages resulting from use of the pumps in
such applications.
10/2016
Edition
KTF25 ... KTF83
Industry water, (warm, cold, with
and without chemical admixtures,
destilled, de-ionized).
2
...12 mm
/s
-10 ... + 60 °C
2 mm
max. 0.1 %
1% of Q max.
The pumps are not suitable for
dry running.
Motors less 3 kW
max. 200
40 °C
1000 m
ATTENTION
Page 2 of 9

Advertisement

Table of Contents
loading

Table of Contents