Suunto D5
Dive counter: 0 to 99 for repetitive dives
•
No-decompression time: 0 to 99 min (>99 above 99)
•
Ceiling depths: 3.0 to 200 m / 10 to 656 ft
•
Ascent time: 0 to 999 min (>999 after 999)
•
Calendar clock
Accuracy: ± 5 s/month (0 °C to 50 °C / 32 °F to 122 °F)
•
12/24 h display
•
Compass
Accuracy: +/- 15°
•
Resolution: 1°
•
Max. tilt: 45 degrees
•
Balance: global
•
Timer
Accuracy: 1 second
•
Display range: 0'00 – 99'59
•
Resolution: 1 second
•
Logbook
Sample rate. 10 seconds
•
Sample rate freedive: 1 second
•
Memory capacity: approximately 200 hours of diving or 400 dive logs, whichever comes
•
first
Tissue calculation model
Suunto Fused™ RGBM 2 algorithm (developed by Suunto and Bruce R. Wienke, BSc, MSc,
•
PhD)
15 tissue compartments
•
•
Tissue compartment halftimes for nitrogen: 1, 2, 5, 10, 20, 40, 80, 120, 160, 240, 320, 400,
480, 560 and 720 min. The on-gassing and off-gassing halftimes are the same.
Tissue compartment halftimes are divided by a constant factor to obtain helium halftimes.
•
Reduced gradient (variable) M-values based on diving habit and dive violations. The M-
•
values are tracked up to 100 hours after a dive
The exposure calculations (CNS% and OTU) are based on recommendations by R.W.
•
Hamilton, PhD and currently accepted exposure time limit tables and principles.
Battery
Type: rechargeable lithium-ion
•
Battery life:
•
fully charged: up to 6-12 h diving or 6 days in time mode
56