3 × 3 Filter
Enabling writing the filter
Write the following three commands in sequence.
Address
Data
F0F30000
08004600
F0F30004
0031FFFF
F0F30008
80000000
Disabling writing the filter
Write the following three commands in sequence.
Address
Data
F0F30000
08004600
F0F30004
0031FFFF
F0F30008
00000000
When writing of the filter is enabled, the addresses
0xF0F62000 to 0xF0F62024 that store the filter table
become open.
F0F62000
F0F62004
Top left
Top
F0F62010
F0F62014
Left
Center
F0F6201C
F0F62020
Bottom left
Bottom
The filter coefficients are specified with 16 bits from
0x0000 to 0xFFFF.
The most significant bit of the 16 bits represents a sign,
the following 7 bits are the integer portion, and the least
significant 8 bits are the fractional portion.
0100: 1.0
FF00: –1.0
0080: 0.5
0040: 0.25
The filter written here is read out when the optical filter
is set to 8.

Display of Test Chart

Displaying the color bar
Write the following three commands in sequence.
Address
F0F30000
F0F30004
F0F30008
Displaying the gray scale
Write the following three commands in sequence.
Address
F0F30000
F0F30004
F0F30008
Turning off the test chart
Write the following three commands in sequence.
Address
F0F62008
Top right
F0F30000
F0F62018
F0F30004
Right
F0F30008
F0F62024
Bottom right
Data
08004600
0037FFFF
80000001
Data
08004600
0037FFFF
80000002
Data
08004600
0037FFFF
00000000