Power Supply Modules - Cisco Firepower 4100 Series Hardware Installation Manual

Hide thumbs Also See for Firepower 4100 Series:
Table of Contents

Advertisement

Power Supply Modules

Cable and operating
distance

Power Supply Modules

The Firepower 4100 supports two AC or DC power supply modules so that dual power supply redundancy
protection is available. Facing the back of the chassis, the power supply modules are numbered left to right,
for example, PSU1 and PSU2.
Note
Do not mix AC and DC power supply modules in one chassis.
Note
After removing power from the chassis either by moving the power switch to OFF or unplugging the power
cord, wait at least 10 seconds before turning power back ON.
Attention
Make sure that one power supply module is always active.
See
Remove and Replace the Power Supply Module, on page 61
the power supply module.
AC Power Supply
The power supplies can supply up to 1100-W power across the input voltage range. The load is shared when
both power supply modules are plugged in and running at the same time. The power supply modules are
hot-swappable.
Table 7: AC Power Supply Module Hardware Specifications
Input voltage
Maximum current
Maximum output power
Cisco Firepower 4110, 4120, 4140, and 4150 Hardware Installation Guide
18
Core diameter (microns)
Modal bandwidth
(MHz/km
G.652
Single mode
100 to 240 V AC
13 A (at 100 V AC)
The system power requirements are lower than the power
Note
supply module capabilities. See
page 23
for the system power requirements.
1100 W
Cable distance
Note
5 km
for the procedure for removing and replacing
Hardware Specifications, on
Overview
Half the
distance
specified by
the IEEE
standard.

Hide quick links:

Advertisement

Table of Contents
loading