Counter Reset - Panasonic LP-400 Series External Control Manual

Laser marker
Hide thumbs Also See for LP-400 Series:
Table of Contents

Advertisement

2-4-8 Counter reset

ON
TRIG. IN
OFF
ON
SELECT 0 to 2 IN
OFF
ON
D0 to D7 IN
(Counter No.)
OFF
ON
SET IN
OFF
ON
READY OUT
OFF
ON
MARKING OUT
OFF
ON
SET OK OUT
OFF
Item
Time
T1
10ms or more
T2
0ms or more
T3
2 to 510ms
T4
T5
0.5ms or more
*1 : To reset the counter, set SELECT 0 to 2 as follows.
Number input target
Counter reset No.
*2 : Specify the counter No. to be reset at D0 to D7. Refer to "Operation of input signal on I/O connector" (P.34) for the detail.
T1
Remarks
Keep the ON status for 10ms or more.
Keep the input until the SET OK is turned to ON.
One-shot output. Set the output time on the environment setting screen. There is a
margin for the setting value.
• When laser pumping is completed
Period for creating marking data. It varies depending on the quantity of data to be
marked.
• When laser pumping is not completed
Period for creating marking data or period until the laser pumping is completed. The
longer one of the two above is employed.
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN
to D7 IN, turn on SET IN.
SELECT 0 (No. 20)
OFF
ME-LP400V-EX-6
*1
*2
T5
T2
T4
T3
SELECT 1 (No. 21)
OFF
SELECT 2 (No. 22)
ON
51