Lp-4X1/Lp - Panasonic LP-400 Series External Control Manual

Laser marker
Hide thumbs Also See for LP-400 Series:
Table of Contents

Advertisement

⿎ Arbitrary point radiation condition : PRF
Sets X/Y coordinate offset and laser power correction ratio, etc. for the specified arbitrary point radiation condition.
• Setting / Readout data of general condition
Sub
STX
PRF
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of processing condition
STX
PRF
R
Data length
Name
[byte]
Point radiation
condition No.
System
reservation
X offset
Y offset
Laser power
correction
(Laser pulse cycle
correction)
(Only for LP-V
series)
* For the detail of the model type, refer to "Target laser marker" (P.8).
[Point radiation condition No.] [System reservation]
[X offset] [Y offset] [Laser power correction]
[Laser pulse cycle correction]
25-byte (LP-V series), 22-byte (LP-400/LP-W series)
[Point radiation condition No.]
2-byte
2
"00"–"15"
1
"0" fixed
Model type*
8
LP-V10
LP-4x0
LP-4x5/LP-V15
8
LP-4x1/LP-W
3
"000"–"200" [%]
(3)
"050"–"200" [%]
(Check
sum)
Description
Setting range [mm]
"-045.000"–"+045.000"
"-055.000"–"+055.000"
"-080.000"–"+080.000"
"-027.500"–"+027.500"
ME-LP400V-EX-6
(Check
sum)
Delimiter
Remarks
System reservation field.
• The correction ratio is calculated
using the value set at the laser
setting as 100%.
• With LP-400/LP-W series,
nothing should be input in Laser
Pulse Cycle Correction.
Delimiter
119