Clearance for installation

Clearance for installation by windows
When installing a semi-outdoor unit near windows, maintain the clearance in order to secure air flow.
• Clearance from windows (A): 100 mm or more
• Clearance from the ceiling (B): 300 mm or more
• Clearance from the floor (C): 100 mm or more
• Keep the ambient temperature at 0 - 30 °C, clear of obstacles that may affect air flow.
– If the unit is subjected to excess heat due to an insufficient gap, this may cause a malfunction, which will not be
covered by the warranty.
– The product may overheat when used with an enclosure unit. Make sure to contact Samsung for guidance in
using enclosure units.
Air-conditioner
B
A
C
Clearance for wall mounting
– Contact Samsung Customer Service Centre for further details.
Installation requirements for wall mounting
A
- at least 60 mm
B
(ambient temperature measuring point) - below 30 °C
– When mounting to a wall surface, the clearance between the product and the wall should
be at least 60 mm at all times and the ambient temperature should not be exceed 30 °C.
English - 4
OM46N / OM55N
A
B

Hide quick links: