COMMISSIONING REPORT
Site details / Informations site
Site / Site
.............................................
Unit Ref/ N° Affaire
..............................................
Installer/ Installateur
.............................................
(1) ROOF INSTALLATION / INSTALLATION SUR LE TOIT
Sufficient Access OK / Accès Suffisants
Yes/Oui
No/ Non
(2) CONNECTIONS CHECK / VERIFICATIONS DE RACCORDEMENTS
Phase check/ Vérification des Phases
Yes / Oui
No / Non
(3)CLIMATIC CONFIGURATION CHECK / VERIFIER LA CONFIGURATION CLIMATIC
CLIMATIC 50 Configured according to the Options and Specifications / CLIMATIC 50 configuré en fonction des options et des
spécifications:
(4) SUPPLY BLOWER SECTION / VENTILATION TRAITEMENT
Type / Type:
Power displayed on plate / Puissance affichée sur la plaque:
Voltage displayed on plate / Tension affichée sur la plaque:
Current displayed on plate / Intensité affichée sur la plaque:
Fan Type / Type de Ventilateur:
Displayed Belt Length / Longueur Courroie affichée:
Tension Checked/ Tension Vérifiée:
Alignment Checked / Alignement Vérifié:
Motor Pulley Dia/ Poulie Moteur Dia:
Fan Pulley Dia/ Poulie Ventilateur Dia: D
Fan Speed / Vitesse rotation Ventilateur = Motor rpm x D
Averaged Measured Amps / Intensité Mesurée moyenne:
Shaft Mechanical Power (Refer to airflow balancing)
Puissance Mécanique à l'Arbre (Voir section réglage débit)
Operating point checked / Vérif. Point de fonctionnement:
Estimated Airflow / Estimation Débit d'Air
(5) AIRFLOW PRESS. SENSOR CHECK / VERIF. DES SECURITES PRESSOSTATS D'AIR
Measured pressure drop / Pertes de charge au pressostat
................................. mbar
(6) EXTERNAL SENSOR CHECKS / VERIFICATION DES CAPTEURS EXTERNES
Check electrical connections / Vérification des
connections électriques: Yes/Oui
Supply Temperature / Température Soufflage
Return Temperature / Température reprise
Outdoor Temperature / Température extérieure
(7) MIXING AIR DAMPERS CHECKS / VERIFICATIONS VOLETS DE MELANGE
Dampers open & close freely/
Volets s'ouvrent et se ferment OK
Yes/Oui
No/ Non
Controller/ Contrôleur
Model/Model
Serial No/ No Série
Refrigerant / Réfrigérant
Condensate drain fitted / Drainage condensats
Installé
Voltage between Phases
Tension entre Phases
Yes/Oui
No/ Non
D
M
P
/ D
M
P
Set Points Adjusted / Changement des consignes:
If Yes enter new values/ Si oui noter les nouvelles consignes:
3410: ............
Check and record temp. in menu 2110 / Vérifier et mesurer les
températures. Dans menu 2110:
No/ Non
100% Fresh Air / 100% Air neuf
.............................°C
.............................°C
.............................°C
% Minimum FA:
%minimum Air Neuf:
.................%
Yes/Oui
No/ Non
1 / 2
...................
N°1
KW
........................
V
........................
A
........................
Forward / Action
Backward / Réaction
mm
........................
Yes/Oui
No/ Non
Yes/Oui
No/ Non
mm
........................
mm
........................
rpm
........................
A
........................
W
........................
Yes/Oui
No/ Non
3
........................
m
/h
Yes/Oui
No/ Non
3411: ............
100% return Air / 100% Air repris
Power exhaust checked/
Ventilateur extraction
Yes/Oui
No/ Non
IOM / ROOFTOP BALTIC Series - 0704-E Page 5
........................................
........................................
.......................................
.......................................
Roofcurb / Costière
OK
Not OK/PasOK
2 / 3
1 / 3
...................
...................
N°2
........................
........................
........................
Forward / Action
Backward / Réaction
........................
Yes/Oui
No/ Non
Yes/Oui
No/ Non
........................
........................
........................
........................
........................
Yes/Oui
No/ Non
........................
3412: ............
Yes/Oui
No/ Non
.............................°C
.............................°C
.............................°C
Enthalpy sensor(s) checked/
Control enthalpie installé
Yes/Oui
No/ Non