Kenwood TK-3360 Service Manual page 40

Hide thumbs Also See for TK-3360:
Table of Contents

Advertisement

TK-3360
Receiver Section
Item
Condition
1. Sensitivity
1) Adj item: Low, Low', Center,
High', High (5 points)
SSG output: –70dBm (70.8µV)
SSG MOD: 1.5kHz
2. Sensitivity
1) Adj item: Low, High (2 points)
Check
SSG output: –115dBm (0.4µV)
[Narrow]
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG output: –117dBm (0.32µV)
SSG MOD: 3.0kHz
3. High RSSI
1) Adj item: Center, Low, High
[Narrow]
(3 points)
SSG output: –70dBm (70.8µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG output: –70dBm (70.8µV)
SSG MOD: 3.0kHz
4. Low RSSI
1) Adj item: Center, Low, High
[Narrow]
(3 points)
SSG output: –118dBm (0.28µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG output: –118dBm (0.28µV)
SSG MOD: 3.0kHz
5. Open
1) Adj item: Center, Low, High
Squelch
(3 points)
[Narrow]
SSG output: –119dBm (0.25µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG output: –120dBm (0.22µV)
SSG MOD: 3.0kHz
6. Tight
1) Adj item: Center, Low, High
Squelch
(3 points)
[Narrow]
SSG output: –115dBm (0.40µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG output: –116dBm (0.35µV)
SSG MOD: 3.0kHz
40
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
TX-RX
ANT
(A/3)
DVM
SP/MIC
Oscilloscope
connector
AF VTVM
Adjustment
Parts
Method
FPU
Write
Check
13dB SINAD or more
FPU
Write
Specifi cations / Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents