16BCommissioning
● The output elements have the correct settings for their type (e.g. alignment and
balancing of couplings, belt forces in the case of a belt drive, tooth forces and
tooth face clearance in the case of toothed-wheel power output, radial and axial
clearance in the case of coupled shafts).
● The minimum insulation resistance and minimum clearance values have been
adhered to.
● The grounding and equipotential bonding connections have been established
correctly.
● All fixing screws, connection elements, and electrical connections have been
tightened to the specified torques.
● Lifting eyes that were screwed in have been removed following installation or
secured to prevent them becoming loose.
● The rotor can turn without coming into contact with the stator.
● All touch protection measures for both moving and live parts have been
implemented.
● In cases where the shaft extension is not being used and is, therefore, exposed, it
has been covered and the feather key has been secured to prevent it from being
thrown out.
● If being used, the external fan is ready for operation and connected so that it
rotates in the direction specified.
● The flow of cooling air is not obstructed.
● If a brake is being used, it is functioning correctly.
● The specified mechanical limit speed n
If the design of the machine requires the converter to be assigned in a particular way,
the relevant information will be provided on the rating plate or an additional label.
Note
It may be necessary to perform additional checks and tests in accordance with the
specific situation on site.
54
is adhered to.
max