Interactive Service Menu; Interactive Menus; Installer Programming; User Functions - DSC PowerSeries Neo TL8803GI-EU Installation Manual

Dual path controller
Hide thumbs Also See for PowerSeries Neo TL8803GI-EU:
Table of Contents

Advertisement

Available languages

Available languages

Interactive menus

The "Interactive Services" menu can be used to access information about the TL8803GI module, install or
remove Z-Wave devices and configure or troubleshoot other interactive features.
The menu times out after 20 minutes. Refer to the following tables for the menu options.

Installer programming

Press [*][8][Installer Code][851] to enter Interactive Services menu.
Menu
--Alarm.com Module Status
---Radio
---HSPA Freq.
---SN
---SIM Card
---Version
---Advanced - Network
1
--Z-Wave Setup
--Number of Z-Wave
2
Devices
1
--Add Z-Wave Device
---Remove Z-Wave Device
1
---Z-Wave Home ID
---Extended Range Option
---Communications Test

User functions

Press [*][6][Master Code] to enter User Functions menu. Then scroll to Interactive Services.
Menu
--Alarm.com Module Status
---Radio
---HSPA Freq.
I
NTERACTIVE
Scroll down through the various Alarm.com module information screens.
Signal level, connection status, roaming status, and errors (if any)
HSPA frequency used by the module.
Module serial number. Needed to create or troubleshoot an Alarm.com account.
SIM card number. Sometimes needed to troubleshoot an account. Not applicable to
CDMA radios.
TL8803GI module firmware version and sub-version. Example: 181a; 181 = module
firmware version, a = subversion.
Use only when instructed by Alarm.com Technical Support.
This menu is used to add, remove, and troubleshoot Z-Wave devices and
networks. To control Z-Wave devices via the Alarm.com website and smart phone
apps, you also need to enable Z-Wave services on the account.
The total number of Z-Wave devices currently known to the module.
Press [*] to enter Z-Wave Add Mode. Make sure the device being added is powered
up and within 3 to 6 feet of the panel. Refer to the manufacturer's instructions for
button presses required to enroll devices.
Press [*] to remove an existing Z-Wave device, or to "reset" a Z-Wave device that
1
was previously learned into a different Z-Wave network. Previously enrolled
devices must be reset before they can be enrolled into the module.
Press [*] to query the Z-Wave network Home ID. If the ID is 0, verify that the
module has communicated with Alarm.com and that the Alarm.com account is set
up for Z-Wave.
Press [*] to enable/disable extended range
Press [*] to perform ADC communication test
See Installer Programming section
See Installer Programming section
See Installer Programming section
S
M
ERVICE
Description
Description
- 21 -

Interactive Service Menu

ENU

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents