Interactive Service Menu

Interactive menus

The "Interactive Services" menu can be used to access information about the TL8803GI module, install or
remove Z-Wave devices and configure or troubleshoot other interactive features.
The menu will time out after 20 minutes. Refer to the following tables for the menu options.

Installer programming

Press [*][8][Installer Code][851] to enter Interactive Services menu.
Menu
--Alarm.com Module Status
---Radio
---HSPA Freq.
---SN
---SIM Card
---Version
---Advanced - Network
1
--Z-Wave Setup
--Number of Z-Wave
2
Devices
1
--Add Z-Wave Device
---Remove Z-Wave Device
1
---Z-Wave Home ID
---Extended Range Option
---Communications Test

User functions

Press [*][6][Master Code] to enter User Functions menu. Then scroll to Interactive Services.
Menu
--Alarm.com Module Status
---Radio
I
NTERACTIVE
Scroll down through the various Alarm.com module information screens.
Signal level, connection status, roaming status, and errors (if any)
HSPA frequency used by the module
Module serial number. Needed to create or troubleshoot an Alarm.com account
SIM card number. Sometimes needed to troubleshoot an account. Not applicable to
CDMA radios
TL8803GI module firmware version and sub-version. Example: 181a; 181 = module
firmware version, a = subversion
Use only when instructed by Alarm.com Technical Support.
This menu is used to add, remove, and troubleshoot Z-Wave devices and
networks. To control Z-Wave devices via the Alarm.com website and smart phone
apps, you will also need to enable Z-Wave services on the account
The total number of Z-Wave devices currently known to the module
Press [*] to enter Z-Wave Add Mode. Make sure the device being added is powered
up and within 3 to 6 feet of the panel. Refer to the manufacturer's instructions for
button presses required to enroll devices
Press [*] to remove an existing Z-Wave device, or to "reset" a Z-Wave device that
1
was previously learned into a different Z-Wave network. Previously enrolled
devices must be reset before they can be enrolled into the module
Press [*] to query the Z-Wave network Home ID. If the ID is 0, verify that the
module has communicated with Alarm.com and that the Alarm.com account is set
up for Z-Wave.
Press [*] to enable/disable extended range
Press [*] to perform ADC communication test
See Installer Programming section