CONNECTIONS – PLUMBING
A disconnection union must always be provided at the cold water inlet, solar
cold water outlet, solar hot water inlet and hot water outlet on the water
heater to allow for disconnection of the water heater.
This water heater has either a plastic dip tube or fitting liner in the inlet and
outlet fittings (see diagram). These must be in place for the water heater to
function properly. Do not remove or damage them by using heat nearby.
They will be pushed into the correct position as the fitting is screwed in.
This water heater is intended to be permanently connected to the water mains and not connected by a hose-
set. A braided flexible hose or semi-flexible connector may be used for connection to the water heater, where
permitted by AS/NZS 3500.4.
IN-SERIES BOOSTER – INTEGRATED
A braided hose, 750 mm long 12 mm diameter, is supplied for connecting between the solar storage tank and
a Rheem 8748 series 20 litre or 26 litre model in-series gas booster mounted onto the storage tank.
It is recommended to install the fittings associated with the solar control unit prior to mounting the in-series gas
"Installation – Solar Control Unit"
booster. Refer to
fitted prior to mounting the in-series gas booster. Refer to step 12 on page 36.
Fit the wall bracket and secure the solar storage tank to the wall prior to the mounting of an in-series gas
booster to the solar storage tank. Refer to
onto the solar storage tank, refer to
Warning: A model in-series gas booster greater than 26 litre capacity cannot be mounted on the solar
storage tank and may only be installed remotely. The size and weight of the gas booster may cause the solar
storage tank to topple over.
Notes
Numbers in parentheses
page 44.
The braided hose has compression fitting connections.
Use thread sealing tape or an approved thread sealant
on all fittings.
To connect the braided hose to the solar storage tank and
in-series gas booster:
Fit the ¾" x ½" hex nipple (1) to the hot water outlet of
the solar storage tank.
Fit the ½" x ½" elbow (2) to the hex nipple (1),
orientating the elbow downwards.
Fit the ¾" x ½" reducing adaptor (3) to the water inlet of
the in-series gas booster.
Connect one end of the insulated braided hose (4) to
the elbow (2) at the hot water outlet of the solar storage
tank and the other end to the adaptor (3) at the water
inlet to the in-series gas booster.
SUPPLIED WITH 511161 SOLAR STORAGE TANK
Hex nipple ¾" x ½"
1.
Elbow ½" x ½"
2.
Adaptor – ¾" x ½"
3.
Insulated braided hose
4.
on page 34. The service 3-way valve assembly must be
"Wall Bracket"
"Mounting the Gas Booster"
refer to items on diagram
SUPPLIED WITH 511161 SOLAR STORAGE TAN
44
on page 26. To integrate the in-series gas booster
on page 30.
on
WALL
BRACKET
INSULATED
HOSE

Hide quick links: