Control of Sony's Unique
Features
Displaying the Test Chart
Displaying the gray scale
Write the following three commands in sequence.
Address
F0F30000
08004600
F0F30004
0037FFFF
F0F30008
80000002
Turning off the test chart
Write the following three commands in sequence.
Address
F0F30000
08004600
F0F30004
0037FFFF
F0F30008
00000000
User Free Memory
Enabling User free memory
Write the following three commands in sequence.
Address
F0F30000
08004600
F0F30004
0032FFFF
F0F30008
80000001
Disabling User free memory
Write the following three commands in sequence.
Address
F0F30000
08004600
F0F30004
0032FFFF
F0F30008
00000000
When User free memory is enabled, the addresses
0xF0F50000 to 0xF0F500FC become open.
These addresses are available for writing data freely.
The written data are retained even if the power is turned
off.
24
Data
Data
Data
Data
Address
Data
F0F50000
Any data
F0F50004
:
F0F500FC
Vertical Stripe Correction
Enabling vertical stripe correction
Write the following 3 commands in sequence.
Address
Data
F0F30000
08004600
F0F30004
0040FFFF
F0F30008
80000000
Disabling vertical stripe correction
Write the following 3 commands in sequence.
Address
Data
F0F30000
08004600
F0F30004
0040FFFF
F0F30008
00000000
Blemish Correction
Generating blemish correction data for
user settings
1
Set all corrections to OFF.
2
Set image format mode.
Specify the following - Format7 Mode0 Mono8
768 × 480 Packet Size 3072.
3
Set the shooting conditions.
Close the lens.
Adjust gain and shutter etc. to match the use
conditions.
4
Set the threshold value.
Set it according to the use environment.
Write the following 3 commands in sequence.
Address
Data
F0F30000
08004600
F0F30004
0044FFFF
F0F30008
00000ddd
ddd = 000h to 3FFh