Call Levels Of F-Fbs/F-Fcs; Call Sequence Of The Blocks In The Main Safety - Siemens SIMATIC S7-1200 Safety Programming Manualline

Hide thumbs Also See for SIMATIC S7-1200:
Table of Contents

Advertisement

3 Methods for Safety Programming
3.1.2

Call levels of F-FBs/F-FCs

For standard user programs, the number of call levels is limited depending on the
CPU. For safety programs, you can use a maximum of eight call levels. A warning
appears when this limit is exceeded and an error message is displayed for pure FC
and multi-instance call chains.
System instructions ("ESTOP1", "SF_DOOR", etc.) are not included in the number
of call levels.
Note
On the system side, functions are mapped as FBs with a multi-instance call in
the protection program; this is the reason why an error message is also
displayed for FC call chains with more than eight call levels.
The program structure in
relatively flat so that the safety program remains within the limit specified here.
3.1.3

Call sequence of the blocks in the Main Safety

Recommendation
Within the Main Safety, call blocks in the following sequence:
1. Receive blocks from other CPUs (F-CPU-F-CPU communication)
2. Error acknowledgment/reintegration of F-modules/F-channels
3. Evaluation block of the sensors
4. Operating mode evaluation
5. Logic operations, calculations, evaluations, etc.
6. Control blocks for safe actuators
7. Send blocks to other CPUs (F-CPU-F-CPU communication)
Safety Programming Guideline
Entry ID: 109750255,
V1.0,
Figure 3-1
10/2017
shows one way of keeping the call levels
16