Table 5- 23
Terminal block X14, interface to the load
Connection
Signal
X14.1
BR L
X14.2
BR N
Max. connectable cross-section 2.5 mm
Danger to life if the permissible cable length of the brake control is exceeded
If the permissible cable length of the brake control is exceeded this can result in death or
serious injury in the event of an error.
• The maximum permissible cable length of 300 m between the 230 VAC Safe Brake
• To accurately calculate the maximum cable length, see the SINAMICS Low Voltage
Table 5- 24
Terminal block X15, fast de-energization
Connection
Signal
X15.1
AUX1
X15.2
AUX2
Max. connectable cross-section 2.5 mm
Spare fuse
The type of spare fuse is as follows: 2 A, time-lag.
Note
Correctly mounting the housing cover after replacing a fuse
An adhesive label is provided on the housing cover indicating the position of the connector.
Mount the cover in the correct position so that the inscription of the label matches the actual
connectors.
Safety Integrated
Function Manual, 07/2016, A5E03264275A
Description
Supply voltage: 230 VAC
Current consumption: 2 A, only for brakes with brake rectifier
2
WARNING
Adapter and the brake must be carefully maintained.
Configuration Manual on the customer DVD supplied with the device.
Description
Supply voltage: 230 VAC
Current consumption: 2 A
2
Controlling the safety functions
5.4 Activating "SBC" via the Safe Brake Adapter
89