7.9.
Remove the SD-Board (42 inch)
1. Remove the flexible cables (SD1B, SD2B, SD3B and
SD4B) connected to the SD-Board.
2. Remove the flexible cable (SU11-SD11) and the bridge
connectors (SC42-SD42 and SC46-SD46).
3. Remove the screws (×2
Board.
7.10. Remove the SC-Board
1. Remove the SU-Board, SM-Board and SD-Board. (See
section 7.7., 7.8. and 7.9.)
2. Unlock the cable clampers to free the cable.
3. Disconnect the connector (SC2).
4. Disconnect the flexible cable (SC20).
5. Remove the screws (×6
, ×2
) and remove the SD-
) and remove the SC-Board.
7.11. Remove the SS-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (SS11, SS12, SS23 and
SS34).
3. Disconnect the flexible cables (SS53A and SS56A) (42
inch)/(SS53 and SS56) (37 inch).
4. Remove the molding prop (×1
5. Remove the screws (×5
7.12. Remove the stand brackets
1. Remove the plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered)
with the plasma panel surface facing downward.
2. Remove the stand brackets (left, right) fastening screws
(×4
each) and remove the stand brackets (left, right).
21
).
) and remove the SS-Board.