Random Auto Restart Control; Remote Control Signal Receiving Sound - Panasonic CS-A18DKD Service Manual

Table of Contents

Advertisement

CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD

8.14. Random Auto Restart Control

• If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
• It will start with previous operation mode and airflow direction.
• If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
• This Random Auto Restart Control is not available when Timer is set.
• This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)

8.15. Remote Control Signal Receiving Sound

• Long beep sound will be heard when:-
− Stopping the air conditioner using OFF/ON operation button.
− Stopping the Quiet Mode.
− Stopping the Powerful Mode.
− Stopping the Ion Mode.
• Short beep sound will be heard for other setting.
• To switch off the beep sound:-
Press the "Auto Operation Button" (behind the front grille) continuously for 10 seconds or more ("beep" "beep" will be heard at
the 10th second). Repeat the above if you want to switch on the beep sound.
However, if the "Automatic Operation Button" has been pressed the Automatic operation will be activated. If you do not require
this operation, you may change it by using the remote control.