Flue gas/ventilation air system accessories for balanced flue operation...
A Ventilation air
B Flue gas
A Ventilation air
B Flue gas
Vertical pitched and flat roof outlet, parallel, system size Ø 80/80 mm
&
For installing the Vitopend in an attic (type C
&
The roof outlet may only be used, where the ceiling of the occu-
pied room also forms part of the roof or only the roof structure is
located above the ceiling (pitched attic).
&
When the balanced flue system is routed through roof spaces,
which are not used as accommodation, run the balanced flue
pipe through an additional metal pipe as protection against
mechanical damage (TRGI '86/96, point 5.6.1.2).
VIESMANN
34
1 Boiler flue connection bend (coaxial)
(order separately)
2 External wall terminal (Ø 60/100 mm)
(incl. wall bezels)
3 Balanced flue pipe (Ø 60/100 mm)
1 m long (trim to size)
0.5 m long (trim to size)
4 Protective grille where the flue term-
inal is near public paths
Balanced flue bend (Ø 60/100 mm)
90°
45° (2 pieces)
Balanced flue inspection piece
straight (Ø 60/100 mm)
Balanced flue condensate trap (Ø
60/100 mm)
Drain outlet kit
1 Boiler flue connection bend (coaxial)
(order separately)
2 External wall terminal (Ø 60/100 mm)
(incl. wall bezels)
3 Balanced flue pipe (Ø 60/100 mm)
1 m long (trim to size)
0.5 m long (trim to size)
Balanced flue bend (Ø 60/100 mm)
90°
45° (2 pieces)
Balanced flue inspection piece
straight (Ø 60/100 mm)
Balanced flue condensate trap (Ø
60/100 mm)
Drain outlet kit
&
)
It may also be routed behind a jamb wall or a solid wall of an
32x
attic built as accommodation, if the fire protection class of the
jamb wall corresponds to that of the ceiling (e.g. B30).
It was verified as part of the DIN DVGW type test, that nowhere
on Vitopend or the balanced flue system will surface tempera-
tures higher than 40 K above room temperature occur.
&
Minimum clearances to combustible materials inside the instal-
lation location or in connection with the roof outlet do not have
to be observed.
(cont.)
Part no. 7194 858
Part no. 7194 843
Part no. 7194 841
Part no. 7194 842
Part no. 7337 276
Part no. 7194 836
Part no. 7194 837
Part no. 7194 833
Part no. 7194 846
Part no. 7179 307
Part no. 7194 858
Part no. 7194 843
Part no. 7194 841
Part no. 7194 842
Part no. 7194 836
Part no. 7194 837
Part no. 7194 833
Part no. 7194 846
Part no. 7179 307
VITOPEND 222

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitopend 100 wheaVitopend 200 whkaVitopend 100 wh0a

Table of Contents