King Canada KCG-15000GE Instruction Manual page 14

15,000w v-twin gasoline generator with electric start
Table of Contents

Advertisement

STORAGE continued...
NOTE: If a fuel stabilizer is not used, all gasoline must be drained from the tank and
carburetor to prevent gum deposits from forming on these parts and causing possible
malfunction of the engine. To drain gasoline:
1) Drain the fuel tank and carburetor.
a) Unscrew the fuel tank cap, remove the retaining clip (A) Fig.21 behind the fuel valve,
and disconnect fuel hose (B), empty the fuel tank into an approved gasoline container.
Reinstall parts once tank is empty.
b) To access the carburator, the air cleaner cover (A) Fig.22 must be disassembled and
removed. The engine side cover (B) Fig.22 must also be removed. Undo the 4 acorn
nuts (C) and the 2 top hex. bolts (D) (under the air cleaner cover) and remove engine
cover.
c) Locate the carburetor drain tube (A) Fig.23, and place it in a suitable container.
d) Loosen the carburetor drain screw (A) Fig.24 using a flat head screwdriver.
e) Drain the gasoline from the carburetor into the container.
f) Retighten the carburetor drain screw securely and reinstall the engine cover and air
cleaner cover.
2) Change the engine oil.
3) Remove the spark plugs.
4) Pour a table spoon (5-10cc) of clean engine oil into each cylinder.
5) Turn the engine for a few seconds by turning the engine switch to the START position
to distribute the oil in the cylinders.
6) Reinstall the spark plugs.
7) Remove the battery and store it in a cool, dry place. Recharge it once a month.
8) Cover the generator to keep out dust.
Your generator is now ready for prolonged storage.
MAINTENANCE & STORAGE
Figure 21
Figure 22
Figure 23
Figure 24