4 Installation
T25
4.1.2
To open the switch box cover of the
indoor unit
T25
T25
4.1.3

To lower the switch box on the indoor unit

During the installation, you will need access to the inside of the
indoor unit. To have easier front access, put the switch box lower on
the unit as follows:
Prerequisite: The user interface panel and front panel have been
removed.
1 Remove the top panel that keeps the switch box into place at
the top of the unit.
Installation manual
6
2 Tilt the switch box to the front and lift it out of its hinges.
T25
1
3 Place the switch box lower on the unit. Use the 2 hinges located
lower on the unit.
4.2

Mounting the indoor unit

4.2.1

To install the indoor unit

1 Lift the indoor unit from the pallet and place it on the floor. Also
see
"2.1.2 To handle the indoor unit" on
2 Connect the drain hose to the drain. See
drain hose to the drain" on
3 Slide the indoor unit into position.
4 Adjust the height of the leveling feet to compensate for floor
irregularities. The maximum allowed deviation is 1°.
page 4.
"4.2.2 To connect the
page 7.
≤1°