GE616 Proximity Reader

4. Specification

Read Range/Time
Input Voltage/Current
Output Format
External Buzzer
Control Input
External LED
Control Input
LED/Buzzer
Color
Operating
Environment
Overall Size (WxHxD)
Weight

5. Installation

5-1. Mullion/Wall Mount
Drill two 6-32 or M3 holes 3.3"(8.38cm) apart in vertical
and drill one 1/2" hole for the reader cable 1.7"(4.31cm) apart
from the top hole.
(If you have installed electric gang box then skip this step.)
5-2. Put reader cable into the center hole and install the
reader module by using two 6-32 or M3 screws.
5-3. Put bezel into the reader module then push bezel until you
hear the locking sound.
Up to 4"(10cm) / 30ms
DC 5V ~ 17V, Max. 100mA
26 bit Wiegand
Low Active, DC 0 ~ 12V,
Max. 50mA
Low Active, DC 0 ~ 12V,
Max. 50mA
2 Color LED (Red and Green) / Piezo
Buzzer
Silver
-31
~ 149 (
℉ -35
10~90% Humidity, Non-Condensing
1.82"x4.81"x0.87"(46x122x23mm)
0.35lb(160g)
6
Last Update August 24, 2005
~ +65 )