5. INITIALIZE ( Bilingual key)
Mode for changing and checking the initial settings.
(1) Menu in mode
INITIALIZE
Current main menu
SUB VIDEO
Current selected menu
Keys
1
SUB VIDEO (Set using the SET key.)
2
MIRROR_MODE (Inverted Picture mode)
OFF/XY cyclic (OFF at the factory setting) <MMN>/<MMZ>
3
FULL MASK
ON/OFF-cyclic (OFF at the factory setting) <FMY>/<FMN>
5
HOUR METER (Displays the current hours meter) <HMD>
6
BAUD RATE (Sets the RS-232C communication speed with
PC)
1200 to 19200 cyclic (4800) at the factory setting
7
EEPROM INIT. (For manufacturing line only)
8
MASK CONTROL (Automatic mask position change setting)
ON/OFF cyclic (ON at the factory setting) <MCY>/<MCN>
p
STD-RGB (Standard speed (15. 734kHz) RGB enable setting)
ON/OFF (OFF at the factory setting)
q
INTE. MODE (Integrator mode setting)
FREE, ON, LOCK cyclic (FREE at the factory setting)
(Menu OFF)
BS1 FINAL SETUP (factory setting) Set using the Set key
(Recovers the initial setting) Refer to next page. <FST>
BS3 IPQ ADJ (Progressive conversion
parameter adjustment)
Set (1, BS1 )
Sets the mode and moves to the lower level.
Note: 1) Do not change the factory settings for the modes of keys
9 . If changed, the panel may be damaged.
2) Be sure to turn the key 3 FULL MASK off when the power
is turned off.
*
m: 1~5
1→1200bps
2→2400bps
3→4800bps
4→9600bps
5→19200bps
MODE
E A /
Commands
<BRm> *
<NRY>/<NRN>
<IMF>/<IMY>/<IMN>
Not necessary to readjust
Fix at the factory setting
27
PDP-501MX
(2) Parameter adjustments (SUB VIDEO)
Common picture quality adjustment for all input signal modes.
SUB VIDEO
Current selected mode
SUB CONTRAST
Setting parameter
Keys
1
SUB CONTRAST (000 to 127)
2
ACL START
3
ACL GAIN
9
ACL SW ACL SW ON/OFF cyclic
p
VAP GAIN
q
VAP INV
BS3
R SIDE LEV
BS5
G SIDE LEV
BS7
B SIDE LEV
BS11 R FULL LEV
BS13 G FULL LEV
BS15 B FULL LEV
Note: Do not change the factory settings for keys 6 and 8.
If changed, the panel may be damaged.
3
Volume +
Increases the value of the parameter selected for
adjustment
Volume –
Decreases the value of the parameter selected for
adjustment
Set
Memorizes the adjusted value and moves to a
higher level
MODE
E A /
: 127
Adjustment value
(000 to 015)
(000 to 015)
(000 to 007)
Not necessary
(000 to 031)
to readjust
F i x a t t h e
(000 to 255)
factory
(000 to 255)
setting
(000 to 255)
(000/255)
(000/255)
(000/255)
43