Absolute pressure input, with flush-mounted diaphragm
Measured variable
Span (continuously
adjustable) or measuring
range, max. operating
pressure and max. test
pressure
DS III input with PMC connection
Measured variable
Span (continuously
adjustable) or measuring
range, max. operating
pressure and max. test
pressure
1 bar g (14.5 psi g) only in PMC Style Standard, not in Minibolt
1)
Absolute pressure input (from the gauge pressure series)
Measured variable
Span (continuously
adjustable) or measuring
range, max. operating
pressure (in accordance
with 97/23/EC Pressure
Equipment Directive) and
max. test pressure (in
accordance with
DIN 16086)
SITRANS P, DS III series (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434656-02, 12/2012
HART
Gauge pressure
Span
Maximum
operating
pressure
MAWP (PS)
43 ...
2.6 bar a
1300 mbar a
(37.7 psi a)
(17 ...
525 inH
O)
2
160 ...
10 bar a
5000 mbar a
(145 psi a)
(2.32 ...
72.5 psi a)
1 ... 30 bar a
45 bar a
(14.5 ...
(653 psi a)
435 psi a)
Depending on the process connection, the
span may differ from these values
HART
Gauge pressure
Span
Maximum
operating
pressure
MAWP (PS)
0.01 ... 1 bar g
4 bar g
(0.15 ...
(58 psi g)
14.5 psi g)
1)
0.04 ... 4 bar g
7 bar g
(0.58 ...
(102 psi g)
58 psi g)
0.16 ...
21 bar g
16 bar g (2.3
(305 psi g)
... 232 psi g)
HART
Absolute pressure
Span
Maximum
operating
pressure
MAWP (PS)
8.3 ...
1.5 bar a
250 mbar a (3
(21.8 psi a)
... 100 inH
O)
2
43 ...
2.6 bar a
1300 mbar a
(37.7 psi a)
(17 ...
525 inH
O)
2
PROFIBUS PA or Foundation Fieldbus
Maximum test
Measuring
pressure
range
10 bar a
1.3 bar a
(145 psi a)
(18.9 psi a)
30 bar a
5 bar a
(435 psi a)
(72.5 psi a)
100 bar a
30 bar a
(1450 psi a)
(435 psi a)
Depending on the process connection, the
measuring range may differ from these values
PROFIBUS PA or Foundation Fieldbus
Maximum
Measuring
test
range
pressure
6 bar g
1 bar g
(87 psi g)
(14.5 psi g)
10 bar g
4 bar g
(145 psi g)
(58 psi g)
32 bar g
16 bar g
(464 psi g)
(232 psi g)
PROFIBUS PA or Foundation Fieldbus
Maximum
Measuring
test
range
pressure
6 bar a
250 mbar a
(87 psi a)
(100 inH
2
10 bar a
1.3 bar a
(145 psi a)
(18.9 psi a)
Maximum
Maximum test
operating
pressure
pressure
2.6 bar a
10 bar a
(37.7 psi a)
(145 psi a)
10 bar a
30 bar a
(145 psi a)
(435 psi a)
45 bar a
100 bar a
(653 psi a)
(1450 psi a)
Maximum
Maximum
operating
test pressure
pressure
4 bar g
6 bar g
(58 psi g)
(87 psi g)
1)
7 bar g
10 bar g
(102 psi g)
(145 psi g)
21 bar g
32 bar g
(305 psi g)
(464 psi g)
Maximum
Maximum
operating
test pressure
pressure
1.5 bar a
6 bar a
O)
(21.8 psi a)
(87 psi a)
2.6 bar a
10 bar a
(37.7 psi a)
(145 psi a)