NE (mismatch) command enables to combine the steps of unit 1 and 2.
If the signal of input terminal 1 and 2 don't match, forward run command is valid.
Parameter setting
Set to "Disabled" of the My function-S.
Assign the "no function" to the Terminal F.
Use the Terminal F as a simple input terminal (IX1).
Assign the "no function" to the Terminal R.
Use the Terminal R as a simple input terminal (IX1).
Assign the forward run command to the virtual input
terminal 1 (VT1).
Assign the reverse run command to the virtual input
terminal 2 (VT2).
Read IX1 (F) terminal input signal. (LD IX1)
ANDN command
NOP command (no operation)
Transfer the result to the internal terminal 1.
IX
Read IX2 (R) terminal input signal. (LD IX2)
ANDN command
OR command
Transfer the result to the virtual input terminal 1.
IX
Read IX1 (F) terminal input signal. (LD IX1)
AND command
NOP command (no operation)
Transfer the result to the virtual input terminal 2.
IX
Set to "My function-S always ON".