4.1.6 Electronic circuit board thermal protection
The appliance is equipped with a device which constantly measures the
temperature of the electronic circuit board.
If the temperature should exceed preset values, the device will trigger
specific functions to reduce the temperature and allow the ceramic hob to
keep operating correctly.
The following table lists the automatically triggered procedures and the
relative trigger temperature:
Fan switches on at low speed
Fan switches on at high speed
Fan switches back to low speed
Fan switches off
Operating power is reduced from Power function to 9
Operating power is reduced by one point for each
cooking zone
All cooking zones switch off
Cooking zones switch back on at reduced power
All cooking zones return to normal operation
The power displays on the hob flash to signal all operations of this kind.
4.1.7 Ceramic hob thermal protection
Each cooking zone is equipped with a device which constantly measures
its temperature.
If the temperature should exceed preset values, the device will trigger
specific functions to reduce the temperature and allow the ceramic hob to
keep operating correctly.
The following table lists the automatically triggered procedures and the
relative trigger temperature:
Operating power is reduced from Power function to 9
Operating power is reduced by one point
Cooking zone switches off
Power returns to set value
The power displays on the hob flash to signal all operations of this kind.
50
Instructions for the User
Operation
Operation
Trigger
temperature
50 °C
60 °C
55 °C
45 °C
76 °C
85 °C
90 °C
85 °C
80 °C
Trigger
temperature
250 °C
280 °C
300 °C
250 °C