Download Print this page

Mitsubishi Electric FR-A741-5.5K Installation Manualline page 11

Hide thumbs Also See for FR-A741-5.5K:

Advertisement

3.2 Main circuit terminal specifications
3.2.1 Terminal arrangement of the main circuit terminal, power supply and the motor wiring
FR-A741-5.5K, 7.5K
Screw size
Screw size (M4)
L1 L2 L3
Power supply
FR-A741-18.5K to 45K
Screw size
(18.5K to 30K: M6)
37K and 45K: M8)
L1 L2 L3
Power
Motor
supply
ACHTUNG
The power supply cables must be connected to R/L1, S/L2, T/L3. (Phase sequence needs not to be matched.) Never connect the
power cable to the U, V, W of the inverter. Doing so will damage the inverter.
Connect the motor to U, V, W. At this time turning on the forward rotation switch (signal) rotates the motor in the clockwise direction
when viewed on the motor shaft.
(M4)
Charge lamp
Jumper
M
3 ~
Motor
Screw size
(M4)
Charge lamp
Jumper
M
3 ~
FR-A741-11K, 15K
Screw size
(M4)
Screw size (M5)
L1 L2 L3
Power supply
FR-A741-55K
Screw size (M8)
L1 L2 L3
Power supplyg
WIRING
Charge lamp
Jumper
M
3 ~
Motor
Screw size (M4)
Charge lamp
Jumper
M
3 ~
Motor
5

Hide quick links:

Advertisement

loading