14 | English
– Switch the vacuum cleaner off for 6–10 seconds and
then on again. Repeat this several times in succession.
– The pre-filter (22) is cleaned using blasts of air when it is
switched off.
– To work after cleaning the filter, switch the vacuum
cleaner back on.
Maintenance and servicing
Maintenance and cleaning
Pull the plug out of the socket before cleaning or per-
u
forming maintenance on the vacuum cleaner, making
tool adjustments, changing accessories or putting
away the vacuum cleaner. This safety measure prevents
the vacuum cleaner from being started accidentally.
To ensure safe and efficient operation, always keep
u
the dust extractor and the ventilation slots clean.
For the user to carry out maintenance, the vacuum cleaner
needs to be disassembled, cleaned and maintained as far as
this is possible without endangering maintenance personnel
or other persons. Before disassembly, the vacuum cleaner
should be cleaned to prevent any potential hazards. The
room in which the vacuum cleaner is disassembled should
be well ventilated. Wear personal protective equipment
while carrying out maintenance. After completing mainten-
ance, the maintenance area should be cleaned.
An inspection regarding the dust extraction capability must
be carried out at least once a year by the manufacturer or
someone who has been trained, e.g. to check for filter dam-
age, that the vacuum cleaner is tight and that the control unit
is functioning correctly.
Class L vacuum cleaners which were located in dirty environ-
ments should have their exteriors, as well as all their com-
ponents, cleaned or treated with sealant. When performing
maintenance and repair work, all dirty parts that cannot be
cleaned satisfactorily must be disposed of. Such parts must
be disposed of in impermeable bags in accordance with the
valid provisions for disposing of such waste.
In order to avoid safety hazards, if the power supply cord
needs to be replaced, this must be done by Bosch or by a
customer service centre that is authorised to repair Bosch
power tools.
Cleaning the container
– Wipe the container (7) from time to time using a non-ab-
rasive off-the-shelf cleaning product and leave it to dry.
Cleaning the Filters
Regularly emptying the dust container and cleaning the fil-
ters will ensure optimum suction power. If suction power is
not achieved after that, the vacuum cleaner is to be brought
to the after-sales service.
1 609 92A 4NC | (14.08.2018)
Cleaning the pre-filter
– Open the catches (9) and remove the top part of the va-
cuum cleaner (10) (see figure C).
– Remove the pre-filter (22) from the container (7).
– Shake out the pre-filter (22) over a suitable waste bin.
– Insert the pre-filter (22) in the container (7), making sure
that the arrows are pointing towards the hose connection
piece (3).
– Put the top part of the vacuum cleaner (10) on and close
the catches (9).
Cleaning the main filter
– Open the catches (9) and remove the top part of the va-
cuum cleaner (10) (see figure C).
– Turn the filter holder (28) as far as possible in the direc-
tion of rotation
and take the filter holder, together with
the main filter (20), out of the top part of the vacuum
cleaner (10).
– Brush the folds of the main filter (20) with a soft brush.
or
Replace the main filter (20) if damaged.
– Place the filter holder (28), together with the main filter
(20), over the filter basket (29) and turn the filter holder
(28) as far as possible in the direction of rotation
– Put the top part of the vacuum cleaner (10) on and close
the catches (9).
Cleaning the wet filter
To prevent mould growth after wet vacuuming:
– Open the catches (9) and remove the top part of the va-
cuum cleaner (10) (see figure C).
– Leave the top part of the vacuum cleaner (10) to dry thor-
oughly.
– Pull the wet filter (21) out of the filter basket (29).
– Wash the wet filter (21) under running water and then
leave it to dry thoroughly.
– Place the wet filter (21) completely over the filter basket
(29).
– Put the top part of the vacuum cleaner (10) on and close
the catches (9).
Storage and Transport (see figure J1–J2)
– Wrap the power cable around the carrying handle (12).
– Place the suction tubes (26) in the holders (14).
– Place the vacuum hose (15) in the holder (11) around
the top part of the vacuum cleaner.
– Carry the vacuum cleaner by the carrying handle (12) or
pull the vacuum cleaner along behind you on even sur-
faces using the pull strap (4).
– Store the vacuum cleaner in a dry room and secure it so
that it cannot be used by unauthorised persons.
– Put the castor brake (5) down to hold the castors (6) in
place.
.
Bosch Power Tools

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gas 12-25 pl

Table of Contents