Siemens LOGO!Power 6EP1311-1SH13 Operating Instructions Manual

Hide thumbs Also See for LOGO!Power 6EP1311-1SH13:

Advertisement

LOGO!Power
Power supply
LOGO!Power
Operating Instructions
6EP1311-1SH03 5 V/3 A
6EP1311-1SH13 5 V/6.3 A
6EP1321-1SH03 12 V/1.9 A
6EP1322-1SH03 12 V/4.5 A
6EP1351-1SH03 15 V/1.9 A
6EP1352-1SH03 15 V/4 A
6EP1331-1SH03 24 V/1.3 A
6EP1332-1SH43 24 V/2.5 A
6EP1332-1SH52 24 V/4 A
02.2011
C98130-A7560-A999-1-7619
___________________
Overview
Description, device design,
___________________
dimension drawing
___________________
Mounting/Disassembly
Mounting position,
___________________
installation clearances
___________________
Installation
___________________
Applications
___________________
Technical data
___________________
EMC
___________________
Ambient conditions
___________________
Safety
___________________
Certifications
___________________
MTBF
___________________
Environment
___________________
Accessories
___________________
Service & Support
1
2
3
4
5
6
7
8
9
10
11
12
13
14

Advertisement

Table of Contents
loading

Summary of Contents for Siemens LOGO!Power 6EP1311-1SH13

  • Page 1 ___________________ LOGO!Power Overview Description, device design, ___________________ dimension drawing ___________________ Mounting/Disassembly Power supply Mounting position, ___________________ installation clearances ___________________ LOGO!Power Installation ___________________ Applications Operating Instructions ___________________ Technical data ___________________ ___________________ Ambient conditions ___________________ Safety ___________________ Certifications ___________________ MTBF ___________________ Environment ___________________ 6EP1311-1SH03 5 V/3 A Accessories...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Overview

    Overview Description LOGO!Power are powerful power supplies, which - thanks to their flat stepped profile - are extremely flexible for use in a host of applications (for example, in installation distribution boards). The 12 V and 24 V versions are ideal as power supplies for the LOGO! logic modules.
  • Page 4 Overview Safety and warning information WARNING When operating electrical devices, it is inevitable that certain components will carry dangerous voltages. Therefore, failure to handle the units properly can result in death or serious physical injury as well as extensive property damage. Only appropriately qualified personnel may work on or in the vicinity of this equipment.
  • Page 5 Overview Ordering data LOGO!Power regulated power supply 6EP1311-1SH03 5 V / 3 A 6EP1311-1SH13 5 V / 6.3 A 6EP1321-1SH03 12 V / 1.9 A 6EP1322-1SH03 12 V / 4.5 A 6EP1351-1SH03 15 V / 1.9 A 6EP1352-1SH03 15 V / 4 A 6EP1331-1SH03 24 V / 1.3 A 6EP1332-1SH43...
  • Page 6 Overview LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 7: Table Of Contents

    Table of contents Overview..............................3 Description, device design, dimension drawing ..................9 Device description..........................9 Connections and terminal designation..................10 Potentiometer..........................10 Status displays and signaling.......................11 Block diagram ..........................11 Dimensions and weight........................12 Mounting/Disassembly..........................13 Mounting position, installation clearances....................15 Standard mounting position ......................15 Other mounting positions ......................15 Installation ...............................
  • Page 8 Table of contents Environment ............................39 Accessories ............................. 41 Service & Support............................ 43 LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 9: Description, Device Design, Dimension Drawing

    Description, device design, dimension drawing Device description LOGO!Power are primary switched-mode power supplies for connection to a 1-phase AC system or to DC systems. An electronically regulated DC voltage that can be set via a potentiometer is available at the output of the device. The output of the device is isolated, no-load proof and short-circuit proof.
  • Page 10: Connections And Terminal Designation

    Description, device design, dimension drawing 1.2 Connections and terminal designation Connections and terminal designation ① The line input terminals can be used to establish the connection to supply voltage. The ② output terminals to be supplied are used to connect the loads (see also Section Installation (Page 17)).
  • Page 11: Status Displays And Signaling

    Description, device design, dimension drawing 1.4 Status displays and signaling Status displays and signaling Status display Green LED for output voltage OK Signaling ④ Normal operation, output lights up green voltage in setpoint range ④ Supply voltage missing or output voltage is not in setpoint range due to overload Block diagram...
  • Page 12: Dimensions And Weight

    Description, device design, dimension drawing 1.6 Dimensions and weight Dimensions and weight Figure 1-4 Dimension drawing Dimensions (W × H × D) Weight 54 × 90 × 55 mm Approx. 160 g 72 × 90 × 55 mm Approx. 250 g 90 ×...
  • Page 13: Mounting/Disassembly

    Mounting/Disassembly WARNING The LOGO!Power power supplies are built-in units. They must be installed in a casing or control cabinet to which only qualified personnel have access. The devices can be snapped onto standard mounting rail EN 60715 35x7.5/15 for installation in a control cabinet.
  • Page 14 Mounting/Disassembly LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 15: Mounting Position, Installation Clearances

    Mounting position, installation clearances Standard mounting position The device is designed for installation on a standard mounting rail EN 60715 35x7.5/15. The device must be mounted vertically to ensure proper cooling, and with the input terminals and output terminals at the top. A clearance of at least 20 mm should be maintained above and below the device.
  • Page 16 Mounting position, installation clearances 3.2 Other mounting positions Figure 3-3 Mounting position (3) Figure 3-4 Mounting position (4) NOTICE In the case of mounting postilions that deviate from the standard mounting position, reduced mechanical resistance of the devices against vibration and shock must be expected.
  • Page 17: Installation

    Installation WARNING Before installation or maintenance work can begin, the system's main switch must be switched off and measures taken to prevent it being switched on again. If this instruction is not observed, touching live parts can result in death or serious injury. Line-side connection The LOGO!Power power supplies are power packs acc.
  • Page 18: Output-Side Connection

    Installation 4.2 Output-side connection Output-side connection The LOGO!Power power supplies provide an isolated (= non-grounded) SELV (Safety Extra Low Voltage) output voltage at the output. The output of the power supplies is no-load, overload, and short-circuit proof. If overload occurs, the electronic current limitation limits the output current to a maximum value (refer to chapter Technical data, Output (Page 25)).
  • Page 19: Applications

    Applications Parallel connection to increase power rating To enhance performance, two LOGO!Power power supplies of the same type can be galvanically connected in parallel. The following must be observed: ● The cables connected to each power supply at terminals "+" and "-" must have identical lengths and the same cable cross-sections (or the same impedance) up to a common external network junction (terminal strip) if possible.
  • Page 20: Parallel Connection For Redundancy

    Applications 5.2 Parallel connection for redundancy Parallel connection for redundancy The parallel switching of several LOGO!Power power supplies for redundancy is required when the demands for reliability of the supply are particularly high. If a component in the redundant supply fails, the power supply for the loads must be fully accommodated by the remaining component.
  • Page 21: Series Connection For Increased Voltage

    Applications 5.3 Series connection for increased voltage Series connection for increased voltage To achieve a higher output voltage, two LOGO!Power power supplies of the same type can be connected in series. In this case, connect the "-" terminal of the first power supply to the "+"...
  • Page 22 Applications 5.4 Protection against short-time voltage dips LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 23: Technical Data

    Technical data Input Rated voltage e rated 1-phase 100 - 240 V AC wide-range input AC voltage range 85 … 264 V AC Voltage* range DC 110 to 300 V DC Connect/shutdown threshold Typ. 80 V/70 V Overvoltage resistance 2,3 × e rated, 1.3 ms Rated line frequency;...
  • Page 24 Technical data 6.1 Input Figure 6-1 Mains buffering LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 25: Output

    Technical data 6.2 Output Output Rated voltage a rated Controlled, isolated DC voltage 5 V DC, 12 V, 15 V or 24 V Total tolerance ±3 % Static line smoothing Approx. ±0.5 % Static load smoothing Approx. ±1 % Residual ripple 12 V, 15 V, 24 V <...
  • Page 26 Technical data 6.2 Output Figure 6-2 Startup delay/voltage rise Figure 6-3 Output characteristic (typical behavior) The device supplies a constant output voltage until the current limit is reached. In the event of an overload, the output current and the output voltage are reduced. The device does not switch off.
  • Page 27: Closed-Loop Control

    Technical data 6.3 Closed-loop control Closed-loop control Dyn. mains compensation (Ve rated ± 1 5 %) <3% Va Dyn. load compensation (Ia: 10/90/10 %) Typ. ±2% Va Load-step settling time < 20 ms (typ. 0.2 ms) 10 to 90 % •...
  • Page 28: Protection And Monitoring

    Technical data 6.5 Protection and monitoring Protection and monitoring Output overvoltage protection Yes, acc. to EN 60950 Current limitation Typ. 110 % … 130 % of Ia rated when you turn on the power supply overload capability with 150 % of Ia rated for typ. 200 ms Short-circuit protection Characteristic curve up to 0 V Sustained short-circuit current...
  • Page 29: Emc

    Generic standards EN 61000-6-2 Immunity for industrial environments EN 61000-6-3 Emission for residential areas Electrostatic discharges EN 61000-4-2 6 kV contact, 8 kV air Electromagnetic fields EN 61000-4-3 80 to 1000 MHz 10 V/m 1000 to 2000 MHz 3 V/m 2000 to 2700 MHz 1 V/m High-speed transient disturbance EN 61000-4-4...
  • Page 30 LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 31: Ambient Conditions

    Ambient conditions Humidity class Climate class 3K3 to EN 60721, no condensation Ambient temperature -20 ... +70 °C with natural convection Derating: from +55 °C 2 %/K • Tested to: EN 60068-2-1 coldness • EN 60068-2-2 dry heat • EN 60068-2-78 damp heat, constant •...
  • Page 32 Ambient conditions LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 33: Safety

    Safety Primary/secondary isolation Yes, SELV output voltage Ua according to EN 60950 and EN 50178 Test voltage Primary/secondary 3 kV or corresponding DC value Protection class Class II (without protective conductor) Leakage current < 250 µA Degree of protection (EN 60529) IP20 LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 34 Safety LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 35: Certifications

    Certifications Certifications CE marking Yes (2004/108/EC and 2006/95/EC) UL/cUL approval cULus-listed (UL 508, CSA C22.2 No.107.1), File E197259 cURus (UL60950, CSA C22.2 No. 60950) File E151273 NEC Class2 for types: 6EP1311-1SH03 5 V/3 A 6EP1321-1SH03 12 V/1,9 A 6EP1351-1SH03 15 V/1,9 A 6EP1331-1SH03 24 V/1,3 A 6EP1332-1SH43 24 V/2,5 A CSA approval...
  • Page 36 Certifications LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 37: Mtbf

    MTBF Mean Time Between Failures In accordance with SN29500: >3500000 h at 40 °C, rated load, 24-h operation LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 38 MTBF LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 39: Environment

    Environment The device is RoHS-compatible. As a rule, only non-silicon precipitating materials are used. LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 40 Environment LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 41: Accessories

    Accessories No accessories. LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 42 Accessories LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 43: Service & Support

    Service & Support Further information via the home page http://www.siemens.de/sitop/manuals or http://support.automation.siemens.com Phone: +49 (0) 911 895 7222 LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...
  • Page 44 Service & Support LOGO!Power Operating Instructions, 02.2011, C98130-A7560-A999-1-7619...

Table of Contents