Siemens 7SR210 Argus Manual page 15

Overcurrent protection relay, answers for energy, reyrolle protection devices
Hide thumbs Also See for 7SR210 Argus:
Table of Contents

Advertisement

Ordering Information – 7SR220 Directional Overcurrent Relay
Product description
Directional O/C Relay
Multi function overcurrent
and earth fault protection
relay
)
5CT is configured as 3PF + EF + SEF/REF (user selectable setting).
1
)
For ESI48-4 compliance of binary inputs external resistors are required.
2
Siemens Protection Devices Limited
Variants
Protection Product
Overcurrent – Directional
Case I/O and Fascia
1)
E6 case, 5 CT, 4 VT, 3 Binary Inputs / 6 Binary Outputs, 8 LEDs
E8 case, 5 CT, 4 VT, 13 Binary Inputs / 14 Binary Outputs, 16 LEDs
E8 case, 5 CT, 4 VT, 13 Binary Inputs / 14 Binary Outputs, 8 LEDs + 6 Keys
Measuring Input
1/5 A, 63.5/110V, 50/60Hz
Auxiliary voltage
30 to 220V DC, binary input threshold 19V DC
30 to 220V DC, binary input threshold 88V DC
Communication Interface
Standard version – included in all models, USB front port, RS485 rear port
Standard version – plus additional rear F/O ST connectors (x2) and IRIG-B
Standard version – plus additional rear 1x RS485 and IRIG-B
Standard version – plus additional rear 1x RS232 and IRIG-B
Protocol
IEC 60870-5-103 and Modbus RTU (user selectable setting)
IEC 60870-5-103, Modbus RTU and DNP3.0 (user selectable setting)
Protection Function Packages
Standard version – Included in all models
27/59
Under/overvoltage
37
Undercurrent
37G
Ground Undercurrent
37SEF
SEF Undercurrent
46BC
Broken conductor/load unbalance
46NPS
Negative phase sequence overcurrent
47
Negative phase sequence voltage
49
Thermal overload
50BF
Circuit breaker fail
51V
Voltage controlled overcurrent
59N
Neutral voltage displacement
60CTS
CT supervision
60CTS-I
CT Supervision
60VTS
VT supervision
64H
High Impedance REF
67/50
Directional instantaneous phase fault overcurrent
67/50G 67/50N Directional instantaneous earth fault
67/51
Directional time delayed phase fault overcurrent
67/51G 67/51N Directional time delayed earth fault/SEF
74TC
Trip circuit supervision
81
Under/over frequency
81HBL2
2
harmonic block/inrush restraint
nd
Cold load pickup
Programmable logic
Standard version – plus
79
Autoreclose
Additional Functionality
No Additional Functionality
Order No.
7 S R 2 2 0
- 2
▲ ▲
|
|
| |
|
|
| |
|
|
| |
|
| |
2
|
| |
|
| |
| |
2
| |
3
| |
4
| |
| |
|
2
|
|
A
B
□ □
A
- 0
A
▲ ▲
▲ ▲
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
|
C
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
|
| |
1
|
| |
2
|
| |
3
|
| |
4
|
| |
|
| |
| |
1
| |
2
| |
| |
|
C
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
D
|
|
|
A
15

Hide quick links: