GENERAL INFORMATION
This Recess Box fits these Rinnai Water Heater models.
INFINITY 12
INFINITY 16
INFINITY 20
INFINITY 26
INFINITY 26 Touch
INSTALLATION METHOD
1.
Preparation of opening in brickwork:
Height 1030–1050mm, width 382–412mm and depth 150mm.
The box can either be fitted as the brickwork is being laid using
the fold out brick ties (A) to secure the box, or in an existing
wall. For an existing wall, provide an opening in the brickwork
to the above dimensions and fix the box in place by drilling
holes in the sides and fixing in position with suitable flush-
headed masonry anchors.
2.
The gas, cold water inlet and hot water outlet pipes can be
brought through the pipe entry holes panel of the box (B) in
the bottom.
The Rinnai water heater serial number and model
number on the data plate located on the left hand side
of the appliance, MUST be copied to the sticker on
IMPORTANT
the inside of the access panel (C). The serial number
is needed for any warranty or service work.
3.
The Rinnai water heater can now be mounted in the recess
box via the top and bottom heater securing points.
Slide the Rinnai upper water heater stainless steel mounting
bracket through the top of securing slot (D) by guiding the
mounting bracket through the slot cut-out on the top of the
recess box.
Lower the unit so that the keyhole slots in the lower stainless
steel mounting bracket are securely resting on the two bottom
threaded studs E and over the padlock tab (F).
Hold the Rinnai water heater in place and fit the two 5mm nuts
to each of the threaded studs (E) so that the bottom mounting
bracket on the water heater is held firmly to the back panel of
the box.
4.
Make the gas and water connections to the water heater. On
completion check for gas escapes and water leaks.
5.
Use silicone to seal the pipe entry holes and seal between
the bottom, side and back panels to ensure that no water can
enter the wall cavity. The bottom panel of the box is designed
with a 2° slope towards the front allowing any water that enters
the enclosure to drain out.
6.
To help reduce the risk of theft or damage, attach the supplied
padlock to the padlock tab (F) as required.
B064440
Installation Manual
RBOX06LW RECESS BOX
(PREPAINTED)
REU-AM1220WD
REU-AM1620WD
REU-AM2024WD
REU-AM2626WD
REU-AM2626WDL
1
Opening
Height 1030 ~ 1050
F
B
C
03_114 RBOX06LW IM Issue 3 080319
Width 382 ~ 412
110
~ 40
=
A
Top
View
90
D
A
E
G

Advertisement

loading

Summary of Contents for Rinnai RBOX06LW

  • Page 1 E and over the padlock tab (F). Hold the Rinnai water heater in place and fit the two 5mm nuts to each of the threaded studs (E) so that the bottom mounting bracket on the water heater is held firmly to the back panel of the box.
  • Page 2 Braeside, Victoria 3195 AU45204 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced at least every 2 years.