Disposal

!
WARNING! Children beware!
Before disposing of your old refrigerator:
Dismantle the drawers.
Leave the shelves in the refrigerator so that children cannot climb
inside.
➤ Place the packaging material in the appropriate recycling waste bins wherever
possible.
M
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
applicable disposal regulations.
12

Troubleshooting

The meaning of the red LED (fig. 2 3, page 2)
For operational faults it illuminates several times. The number of pulses depends on
the type of fault.
Each flash lasts for one quarter of a second. After the series of impulses a pause
follows. The sequence for the fault is repeated every four seconds.
Number of
Fault
flashes
1
Supply voltage
2
Excessive fan current
3
The motor doesn't start
4
Speed too low
5
Overheating of the electronics
unit
EN
Possible cause
The supply voltage is outside of the set
range.
The fan loads the electronics unit with more
than 1 A.
The rotor is jammed.
The pressure difference in the cooling system
is too high (> 5 bar).
If the cooling system is overloaded, the
minimum speed of the motor of 1850 RPM
cannot be maintained.
If the cooling system is loaded too heavily or
the temperature is set too high, the electron-
ics can overheat.