Tool And Work Area Set-Up; Operating Instructions For Use Of Jaw Sets; Preparing The Joint; Pressing The Fitting - RIDGID CT400 Operator's Manual

Press tool
Table of Contents

Advertisement

Available languages

Available languages

CT400 Press Tool
Figure 3 – Sliding Jaw Set Into CT400
4. Select the standard series jaw set or actuator that cor-
responds to the fitting system and tubing size. Inspect
the jaw set. If dirty, clean jaw sets. Refer to Main-
tenance Section for cleaning instructions. Failure to
clean jaws can result in an improper connection that
can lead to extensive property damage. If any cracks
are found, discard the damaged jaw set and obtain
replacement.
A jaw that has been welded, grounded,
WARNING
drilled or modified in any manner can shatter during
pressing, resulting in sharp flying objects, severe injury
or death. Discard and replace damaged jaw sets.
5. Slide the jaw set into the press tool (Figure 3).
6. Push the jaw set mounting pin until it clicks.
NOTE! The CT400 will not work unless the pin is fully
engaged.

Tool and Work Area Set-Up

WARNING
To prevent serious injury, proper set-up of the press
tool and work area is required. The following pro-
cedures should be followed:
1. Check work area for:
• Adequate lighting
• Clear path to the electrical outlet that does not
contain any sources of heat or oil, sharp edges or
moving parts that may damage electrical cord.
• Flammable liquids, vapors or dust that may ignite.
2. Plug the Press Tool into the electrical outlet, making
sure to position the power cord along the clear path
selected earlier. If the power cord does not reach the
outlet, use an extension cord in good condition.
WARNING
fires, never use an extension cord that is damaged or
does not meet the following requirements:
• The cord is rated as "W" or "W-A" if being used
outdoors.
• The cord has sufficient wire thickness (16 AWG
below 50'/14 AWG 50'-100'). If the wire thickness is
too small, the cord may overheat, melting the cord's
insulation or causing nearby objects to ignite.
CAUTION
feet is not recommended. May result in low voltage
condition that will cause the tool to malfunction.
CAUTION
peratures below 15°F (-10°C) or above 120°F (50°C).
Tool could malfunction resulting in an improper seal
that can lead to extensive property damage.
Operating Instructions For Use
With Jaw Sets
The CT400 is designed for use only with RIDGID jaw
sets, actuators and press rings. Use the jaw and fit-
ting system intended for the specific tubing material
you are installing.
Keep fingers and hands away from jaws, press
rings and actuator arms during pressing cycle.
Always wear eye protection to protect your eyes
from dirt and other foreign objects.

Preparing the Joint

1. See the appropriate press system operator's manu-
al for proper joint preparations prior to pressing.
Pressing the Fitting With Scissor Jaw Set
1. Plug the CT400 Press Tool into electrical outlet.
2. Make sure the tubing is inserted to the proper depth in
fitting as specified in fitting system operator's manual.
3. Squeeze jaw arms to open the jaw set (Figure 4).
Ridge Tool Company
To avoid electric shock and electrical
Use of extension cords in excess of 100
Do not use the CT400 Press Tool at tem-
WARNING
5